Displays the optical monitored information for a specific interface.
Privileged EXEC mode
The command shows if values for Temperature, Voltage, Current, TX Power, and RX Power have reached threshold limits. The displayed thresholds are High-Alrm, High-Warn, Low-Alrm, or Low-Warn.
To display the global optical monitoring configuration:
SLX# show media optical-monitoring N/A - Not Available. Port Optical Frequency Wavelength Module Supply Channel Bias Channel Monitoring Error Error Temperature Voltage TX Power Current RX Power Support ( GHz ) ( nm ) ( C ) ( mVolts ) ( uWatts / dBm ) ( mAmps ) ( uWatts / dBm ) =========== ========== ========= ========== =========== ========== =========================== ========= ================= Et 0/20 YES 0.0 0.000 18 3370.8 23.4 / -16.308 0.148 596.8 / -2.242 Normal Normal Low-Alrm Low-Alrm Normal Et 0/21 YES 0.0 0.000 16 3395.1 12.2 / -19.136 0.104 612.1 / -2.132 Normal Normal Low-Alrm Low-Alrm Normal Et 0/31 YES 0.0 0.000 17 3366.7 50.6 / -12.958 0.258 0.0 / -inf Normal Normal Low-Alrm Low-Alrm Low-Alrm Et 0/34 YES 0.0 0.000 19 3369.5 57.9 / -12.373 0.270 508.5 / -2.937 Normal Normal Low-Alrm Low-Alrm Normal Et 0/35 YES 0.0 0.000 20 3352.7 0.1 / -40.000 0.002 519.2 / -2.847 Normal Normal Low-Alrm Low-Alrm Normal Et 0/37 YES 0.0 0.000 19 3347.9 0.1 / -40.000 0.002 0.4 / -33.979 Normal Normal Low-Alrm Low-Alrm Low-Alrm Et 0/38 YES 0.0 0.000 20 3349.3 31.2 / -15.058 0.210 0.0 / -inf Normal Normal Low-Alrm Low-Alrm Low-Alrm Et 0/45 YES 0.0 0.000 19 3432.4 23.8 / -16.234 0.214 655.1 / -1.837 Normal Normal Low-Alrm Low-Alrm Normal Et 0/47 YES 0.0 0.000 15 3350.9 0.1 / -40.000 0.002 0.1 / -40.000 Normal Normal Low-Alrm Low-Alrm Low-Alrm Et 0/48 YES 0.0 0.000 19 3350.7 38.4 / -14.157 0.270 557.4 / -2.538 Normal Normal Low-Alrm Low-Alrm Normal Et 0/51 YES 0.0 0.000 22 3342.6 Aggregate 0.0 / -inf 145.548 3455.7 / 5.385 Normal Normal High-Alrm High-Alrm High-Alrm Channel[1] 0.0 / -inf 23.854 710.4 / -1.485 Channel[2] 0.0 / -inf 54.148 784.5 / -1.054 Channel[3] 0.0 / -inf 37.638 989.9 / -0.044 Channel[4] 0.0 / -inf 29.908 970.9 / -0.128 Et 0/55 YES 0.0 0.000 23 3334.5 Aggregate 0.0 / -inf 179.714 3830.7 / 5.833 Normal Normal High-Alrm High-Alrm High-Alrm Channel[1] 0.0 / -inf 22.484 949.8 / -0.224 Channel[2] 0.0 / -inf 58.480 948.8 / -0.228 Channel[3] 0.0 / -inf 54.228 689.9 / -1.612 Channel[4] 0.0 / -inf 44.522 1242.2 / 0.942 SLX#
To display the optical monitoring configuration for an interface, use the following command:
SLX# show media optical-monitoring interface ethernet 0/20 N/A - Not Available. Port Optical Frequency Wavelength Module Supply Channel Bias Channel Monitoring Error Error Temperature Voltage TX Power Current RX Power Support ( GHz ) ( nm ) ( C ) (mVolts) (uWatts) (mAmps) (uWatts/dBm) =========== ========== ======== ========== =========== ========== ======== ============ Et 0/20 YES 0.0 0.000 18 3371.4 24.7/-16.073 0.142 595.3/-2.253 Normal Normal Low-Alrm Low-Alrm Normal SLX# SLX# show media optical-monitoring interface ethernet 0/51 N/A - Not Available. Port Optical Frequency Wavelength Module Supply Channel Bias Channel Monitoring Error Error Temperature Voltage TX Power Current RX Power Support ( GHz ) ( nm ) ( C ) ( mVolts ) ( uWatts / dBm ) ( mAmps ) ( uWatts / dBm ) =========== ========== ========= ========== =========== ========== =========================== ========= ================= Et 0/51 YES 0.0 0.000 22 3341.3 Aggregate 0.0 / -inf 145.548 3460.3 / 5.391 Normal Normal High-Alrm High-Alrm High-Alrm Channel[1] 0.0 / -inf 23.854 711.6 / -1.478 Channel[2] 0.0 / -inf 54.148 794.5 / -0.999 Channel[3] 0.0 / -inf 37.638 995.6 / -0.019 Channel[4] 0.0 / -inf 29.908 958.6 / -0.184 SLX#