To set or override the MeshPoint Auto-channel Selection policy settings:
Channel Width | Set the channel width the meshpoint‘s automatic channel
scan assigns to the selected radio. Available options
include:
|
Priority Meshpoint | Configure the meshpoint monitored for automatic channel scans. This is the meshpoint assigned priority over other available mesh points. When configured, a mesh connection is established with this mesh point. If not configured, a meshpoint is automatically selected. |
Off-channel Duration | Set the duration (from 20 - 250 milliseconds) the scan dwells on each channel when performing an off channel scan. The default is 50 milliseconds. |
Off-channel Scan Frequency | Set the duration (from 1- 60 seconds) between two consecutive off channel scans. The default is 6 seconds. |
Meshpoint Root: Sample Count | Configure the number of scan samples (from 1- 10) for data collection before a mesh channel is selected. The default is 5. |