To set or override the MeshPoint Path Method SNR settings:


| Channel Width | Set the channel width the meshpoint‘s automatic channel
										scan assigns to the selected radio. Available options
											include:
  | 
								
| Priority Meshpoint | Configure the meshpoint monitored for automatic channel scans. This is the meshpoint assigned priority over other available mesh points. When configured, a mesh connection is established with this mesh point. If not configured, a meshpoint is automatically selected. | 
| SNR Delta | Set the SNR ratio delta (from 1 - 100 dB) for mesh path
										selections.  When path selection occurs, the defined value is utilized for selecting the optimal path. A better candidate, on a different channel, must have a signal strength that exceeds this delta value when compared to the signal strength of the next hop in the mesh network. The default setting is 5 dB.  | 
								
| SNR Threshold | Set the SNR threshold for mesh path selections (from -100
										to 0 dB).  If the signal strength of the next mesh hop falls below this set value, a scan is triggered to select a better next hop. the default setting is -65 dB.  | 
								
| Off-channel Duration | Set the duration (from 20 - 250 milliseconds) the scan dwells on each channel when performing an off channel scan. The default is 50 milliseconds. |