To set or override the MeshPoint Path Method Root Path Metric configuration:
Channel Width | Set the channel width the meshpoint‘s automatic channel
scan assigns to the selected radio. Available options
include:
|
Priority Meshpoint | Configure the meshpoint monitored for automatic channel scans. This is the meshpoint assigned priority over other available mesh points. When configured, a mesh connection is established with this mesh point. If not configured, a meshpoint is automatically selected. |
Meshpoint: Path Minimum | Set the minimum path metric (from 100 - 20,000) for establishing mesh connections. The default setting is 1000. |
Meshpoint: Path Metric Threshold | Configure a minimum threshold (from 800 - 65535) for triggering an automatic channel selection for meshpoint selection. The default is 1500. |
Meshpoint: Tolerance Period | Configure the duration to wait before triggering an automatic channel selection for the next hop. The default is 1 minute. |
Meshpoint Root: Sample Count | Set the number of scans (from 1- 10) for data collection before a mesh point root is selected. The default is 5. |
Meshpoint Root: Off-channel Duration | Configure the duration (from 20 - 250 milliseconds) that the scan dwells on each channel when performing an off-channel scan. The default is 50 milliseconds. |
Meshpoint Root: Channel Switch Delta | Configure the delta (from 5 - 35 dBm) that triggers a meshpoint root automatic channel selection when exceeded. The default is 10 dBm. |
Meshpoint Root: Off-channel Scan Frequency | Configure the duration (from 1 -60 seconds) between two consecutive off channel scans for meshpoint root. The default is 6 seconds. |
Meshpoint Root: Channel Hold Time | Set the minimum duration (from 0 - 1440 minutes) to remain on a selected channel before channel conditions are reassessed for a possible channel change. Set this value to zero (0) to prevent an automatic channel selection from occurring. The default is 30 minutes. |