This command displays the current temperature of the power supply controllers and the switch.
On a stack, the command displays the current temperature of the switches in each slot.
This command has no arguments or variables
N/A.
Depending on the software version running on your switch or your switch model, additional or different temperature information might be displayed.
Use this command to display the temperature in Celsius and the current status of the standalone switch or all switches in a stack.
Temperature information for bridge port extenders (BPEs) does not appear in this command. Use the show vpex bpe {slot slot_num} {environment} command instead.
The following is sample output from a SummitStack of 8 nodes:
Slot-3 Stack.1 # show temperature Field Replaceable Units Temp (C) Status Min Normal Max -------------------------------------------------------------------------- Slot-1 : Slot-2 : SummitX 34.50 Normal -10 0-54 59 Slot-3 : SummitX 36.50 Normal -10 0-66 67 Slot-4 : Slot-5 : Slot-6 : Slot-7 : Slot-8 : Slot-3 Stack.2 #
This command was first available in an ExtremeXOS 10.1.
Information about the power controller(s), a component status column, and the minimum, normal, and maximum temperature ranges of the components was added to the output in ExtremeXOS 11.0.
Support for stacking was added to output in ExtremeXOS 12.0.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X690, and X695 series switches.