Allows you to associate a bridge port extender (BPE) to a slot.
vpex | Specifies Virtual Port Extender (VPEX). |
ports | Specifies the switch ports attached to the BPE. |
port_list | Specifies the switch ports attached to the BPE. Must be in the
format slot:port. Only a single port can be configured at a time. Note: If the switch port is a LAG, the
port specified must be the master port.
|
slot | Specifies VPEX BPE slot assignment. |
slot_num | Specifies VPEX BPE slot assignment. Value must be between 100–162. |
N/A
You must enable VPEX mode (enable vpex) before using this command.
The behavior of this command is similar to assigning slots within a chassis. After assigning a slot number to the port extender, you can make port-level configuration choices with the familiar slot:port notation in other commands involving the port extender's ports (for example, configure vlan v1 add port 100:1).
This command causes jumbo frames to be enabled on the specified ports.
The following example assigns a BPE attached to switch port 1:23 to slot 100:
# configure vpex ports 1:23 slot 100
This command was first available in ExtremeXOS 22.5.