Stops DMM frame transmission.
segment_name |
An alpha numeric string identifying the segment name. |
mep mep_id |
Specifies the maintenance association End Point that helps trigger a particular MEP level session on that segment. The range is 1-8191. The default is all MEPs on the segment. |
N/A.
Use this command to stop transmission of DMM frames for a selected CFM segment. This command stops transmission that has been triggered using the command enable cfm segment frame-delay measurement.
This stops the transmission for both continuous and on-demand mode.
The following command stops frame transmission on the CFM segment segment-first:
disable cfm frame-delay measurement segment-first
This command was first available in ExtremeXOS 12.3.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X690, and X695 series switches.