Allows you to disassociate a bridge port extender (BPE) from a slot number assignment.
vpex | Specifies Virtual Port Extender (VPEX). |
ports | Specifies switch ports attached to BPEs. |
port_list | Specifies switch ports attached to BPEs.
Must be in the format slot:port. Note: If the switch port is a LAG, the port
specified must be the master port.
|
slot | Specifies the BPE slot assignment. |
N/A.
The behavior of this command is similar to removing slots within a chassis. After executing this command, the BPE no longer occupies the slot number assignment.
The following example removes the slot number assignment from a BPE attached to switch port 1:23:
# unconfigure vpex ports 1:23 slot
This command was first available in ExtremeXOS 22.5.