configure inline-power priority
ports
configure inline-power priority [critical | high | low] ports port_list
Description
Sets the This command is available
on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, and X620 series
switches. priority on the specified
ports.
Syntax Description
critical | high | low
|
Sets the PoE priority for the
specified ports. |
port_list
|
Specifies one or more ports or
slots and ports. |
Usage Guidelines
The system allocates power to those ports with the highest priorities
first. This command can also be used in conjunction with the configure inline-power disconnect-precedence command.
If you configure the disconnect precedence as lowest priority, then newly detected
PDs will be powered if that port has higher priority than the existing powered
ports.
If
there are multiple ports at the same priority level (either configured
or by default) and one of the ports must have power withdrawn because
of excessive power demands, those ports with the lower port number
are powered first. The higher port numbers have power withdrawn
first in the case of equal PoE port priorities.
Example
The following command assigns a critical PoE priority on ports 4 – 6 on
slot 3 on a SummitSwitch:
configure inline-power priority critical ports 3:4-3:6
History
This command was
first available in ExtremeXOS 11.1.
Platform Availability
This command is available on:
- ExtremeSwitching
X450-G2-24p-GE4—ExtremeXOS 16.1 and
later.
- ExtremeSwitching
X450-G2-48p-GE4—ExtremeXOS 16.1 and
later.
- ExtremeSwitching
X450-G2-24p-10GE4—ExtremeXOS 16.1 and
later.
- ExtremeSwitching
X450-G2-48p-10GE4—ExtremeXOS 16.1 and
later.
- ExtremeSwitching
X460-G2-24p-10GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-48p-10GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-24p-GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-48p-GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-16mp-32p-10GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-24p-24hp-10GE4—ExtremeXOS 22.2 and
later.
- ExtremeSwitching
X440-G2-48p-10GE4—ExtremeXOS 21.1 and
later.
- ExtremeSwitching
X440-G2-24p-10GE4—ExtremeXOS 21.1 and later.
- ExtremeSwitching
X440-G2-12p-10GE4—ExtremeXOS 21.1 and
later.
- ExtremeSwitching X465-48P—ExtremeXOS 30.2 and later.
- ExtremeSwitching
X435-8P-4S—ExtremeXOS 30.5 and
later.
- ExtremeSwitching
X435-24P-4S—ExtremeXOS 30.5 and
later.
- ExtremeSwitching
X435-8P-2T-W—ExtremeXOS 30.5 and
later.
- ExtremeSwitching X465-24MU-24W—ExtremeXOS 30.2 and later.
- ExtremeSwitching X465-48W—ExtremeXOS 30.2 and later.
- ExtremeSwitching X465-24MU—ExtremeXOS 30.2 and later.
- ExtremeSwitching X465-24W—ExtremeXOS 30.2 and later.
- ExtremeSwitching
X465i-48W—ExtremeXOS 30.5 and later.