Notifies the CFM that EAPs is interested in notifications for the specified MEP and RMEP pair.
cfm | Connectivity Fault Management. |
add | Add a MEP group. |
delete | Delete a MEP group. |
group group_name | MEP group to bind. |
N/A.
This command notifies CFM that EAPs is interested in notifications for this MEP and RMEP pair. This MEP should already be bound to a physical port, so when notification is received, EAPS associates that notification with a ring-port failure.
The following command deletes the control VLAN keys from the EAPS domain eaps_1:
configure eaps cfm add
This command was first available in ExtremeXOS 15.2.
This command is available on all ExremeXOS platforms; however, not all platforms support hardware-based CFM. Platforms with no hardware-based CFM support are limited to software-based CFM transmit intervals of 100 ms or higher. Hardware-based intervals can go as low as 3.3 ms.