Shows the Syslog parameters for policy rules.
syslog | Designates showing the Syslog parameters for policy rules. |
machine-readable | Shows whether Syslog messages are shown in decimal or hexadecimal format. |
extended-format | Shows whether extended formatting of rule usage messages is enabled or disabled. |
every-time | Shows whether Syslog messages are sent every time a rule is used or just the first time. |
N/A.
None.
The following example shows the Syslog parameters for policy rules:
# show policy syslog Syslog messages will be logged in DECIMAL format. Extended format DISABLED on rule usage messages. Syslog messages sent on EACH USE of rule.
This command was first available in ExtremeXOS 30.2.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X690, and X695 series switches.