Unconfigures the inline power usage alarm threshold and returns threshold to the default value of 70%.
This command has no arguments or variables.
70.
This command unconfigures the This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, and X620 series switches. usage threshold setting for initiating SNMP event and EMS messages and returns the switch‘s inline power usage threshold for to 70%. The system initiates an event and message once that percentage of the budgeted power is being used.
On stand-alone switches, this PoE threshold applies to the entire switch.
The system generates an additional SNMP event and EMS message once the power usage falls below the threshold again; once the condition clears.
The following command resets the inline power usage alarm threshold to 70%:
unconfigure inline-power usage-threshold
This command was first available in ExtremeXOS 11.1
This command is available on the PoE devices listed in Extreme Networks PoE Devices.