Displays inline power information for the specified ports.
port_list | Specifies one or more ports. If you do not specify ports, information for all ports appears. |
N/A.
Note
Ports in the denied or faulted state periodically display the searching state as the hardware retests the PD state.
You can use this command to generate a summary report or a detailed report.
The detail command lists all inline power information for the selected ports.
The following command displays summary inline power information for ports 1 to 3 on a switch:
show inline-power info ports 1-3
The following is sample output from this command:
Port State Class Volts Curr Power Fault (mA) (Watts) 1 delivering class3 48.3 192 9.300 None 2 delivering class3 48.3 192 9.300 None 3 searching ------ 0.0 0 0.0 None
The following command displays detail inline power information for port 1 on slot 3:
show inline-power info detail port 3:1
The following is sample output from this command:
Port 3:1 Configured Admin State: enabled Inline Power State : delivering MIB Detect Status : delivering Label : Operator Limit : 16800 milliwatts PD Class : class3 Max Allowed Power : 15.400 W Measured Power : 9.400 W Line Voltage : 48.3 Volts Current : 193 mA Fault Status : None Detailed Status :
The following command displays detail inline power information for port 27:
# show inline-power info detail ports 27
The following is sample output from this command:
Port 27 Configured Admin State: enabled Inline Power State : delivering MIB Detect Status : delivering Label : Operator Limit : 90000 milliwatts PD Class : class8 Max Allowed Power : 90.0 W Measured Power : 33.300 W Line Voltage : 53.7 Volts Current : 621 mA Fault Status : None Detailed Status : Delivering power to IEEE PD Priority : low Power Up Status : 4-pair 60W Powered Channels : Primary and Alternative Detection : 802.3af-only
The following command displays detail inline power information with class-based configured for port 1:
# show inline-power info detail ports 1
The following is sample output for this command (lines 7 and 9):
Port 1 Configured Admin State: enabled Inline Power State : delivering MIB Detect Status : delivering Label : Operator Limit : class-based (97000 milliwatts when not class-based) PD Class : class6 Max Allowed Power : 60.0 W Measured Power : 49.800 W Line Voltage : 54.2 Volts Current : 919 mA Fault Status : None Detailed Status : Delivering power to IEEE PD Priority : low Power Up Status : 4-pair 90W Powered Channels : Primary and Alternative Detection : 802.3af-only
This command was first available in ExtremeXOS 11.1.
PD classes 7 and 8, and power up status and powered channels information for ExtremeSwitching X465 PoE switches with 60W ('u') and 90W ('w') ports was added in ExtremeXOS 30.2.
class-based information was added in ExtremeXOS 32.3.
This command is available on the This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, and X620 series switches. devices listed in Extreme Networks PoE Devices.