show cfm

show cfm { domain_name { association_name {{ports port_list {[intermediate-point | [end-point [up|down]]]}}}

Description

Displays the current CFM configuration on the switch.

Syntax Description

domain_name Enter the name of the domain you want to display.
association_name IEEE 802.1ag or ITU-T Y.1731 association name.
port_list Enter the ports in the domain and association you want to display.
up Enter this to display the UP MEP for the specified MA.
down Enter this to display the DOWN MEP for the specified MA.
intermediate-point Enter this to display the MIPs for the specified MA.

Default

N/A.

Usage Guidelines

This command displays the following information:
  • Domain names
  • MA levels
  • Association names
  • VLAN names
  • Transmit Interval
  • UP MEPs
  • MEPIDs
  • MEP transmit intervals
  • MEP State
  • DOWN MEPs
  • Intermediate points (MIPs)
  • Total number of CFM ports on the switch
  • Destination MAC Type
  • VPLS-based MPs
  • Sender ID information
  • ISID Intermediate Point

For the number of domains, ports, MEPs, MIPs, and associations supported on the switch, see the Supported Instances for CFM section in the ExtremeXOS 32.6.1 User Guide .

Example

The show cfm command displays the current CFM configuration on the switch:

* switch # show cfm
Domain: "dnsname", MD Level: 2 
    Association: "10", Destination MAC Type: Multicast, VLAN "v1" with 2 cfm ports 
    Transmit Interval: 1000 ms,  Type : IEEE 802.1ag Maintenance Association   
        port 1; Up End Point,   mepid: 100, transmit-interval: 1000 ms (from association)
                MEP State: Enabled, CCM Message: Enabled, Send SenderId TLV: Disabled         
                Faulting State               : No         
                Last Faulting State Change   : Wed Jun 19 09:12:13 2013         
                MEP Error Defects            : None         
                Port Status                  : Up   
          port 15; Intermediate Point ( Dynamic ) 
        Association: "VSNLMEG1", Destination MAC Type: Multicast, VLAN "none" with 0 cfm ports 
        Transmit Interval: 1000 ms,  Type : ITU-T Y.1731 Maintenance Entity Group 
        Association: "snmp_ma_name", Destination MAC Type: Multicast, VLAN "none" with 0 cfm ports 
        Transmit Interval: 1000 ms,  Type : IEEE 802.1ag Maintenance Association
    Domain: "dom1", MD Level: 5 
        Association: "VSNLMEG1", Destination MAC Type: Multicast, VLAN "v2" with 2 cfm ports 
        Transmit Interval: 10 ms,  Type : ITU-T Y.1731 Maintenance Entity Group   
          port 1; Down End Point, mepid: 100, transmit-interval: 3.3 ms (configured)         
                MEP State: Enabled, CCM Message: Enabled, Send SenderId TLV: Disabled         
                Faulting State               : Yes         
                Last Faulting State Change   : Wed Jun 19 09:08:12 2013         
                MEP Error Defects            : Remote         
                Port Status                  : Up
          port 15; Down End Point, mepid: 200, transmit-interval: 10 ms (from association)
                MEP State: Enabled, CCM Message: Enabled, Send SenderId TLV: Disabled         
                Faulting State               : Yes         
                Last Faulting State Change   : Wed Jun 19 09:08:13 2013         
                MEP Error Defects            : Remote         
                Port Status                  : Up 
         Association: "short_ma_name", Destination MAC Type: Multicast, VLAN "v1" with 2 cfm ports 
         Transmit Interval: 1000 ms,  Type : IEEE 802.1ag Maintenance Association   
           port 1; Down End Point, mepid: 100, transmit-interval: 3.3 ms (configured)         
                MEP State: Enabled, CCM Message: Enabled, Send SenderId TLV: Disabled         
                Faulting State               : Yes         
                Last Faulting State Change   : Wed Jun 19 09:09:47 2013         
                MEP Error Defects            : Remote         
                Port Status                  : Up   
           port 15; Down End Point, mepid: 200, transmit-interval: 1000 ms (from association)         
                MEP State: Enabled, CCM Message: Enabled, Send SenderId TLV: Disabled         
                Faulting State               : Yes         
                Last Faulting State Change   : Wed Jun 19 09:09:47 2013         
                MEP Error Defects            : RDI, Remote         
                Port Status                  : Up
    Domain: "dom2", MD Level:  6 
          Association: "VSNLMEG1", Destination MAC Type: Unicast, VLAN "v2" with 2 cfm ports 
          Transmit Interval: 1000 ms,  Type : ITU-T Y.1731 Maintenance Entity Group   
          port 1; Up End Point,   mepid: 100, transmit-interval: 1000 ms (from association)   
                MEP State: Enabled, CCM Message: Enabled, Send SenderId TLV: Disabled         
                Faulting State               : No         
                Last Faulting State Change   : Wed Jun 19 09:39:14 2013         
                MEP Error Defects            : None         
                Port Status                  : Up   
          port 15; Intermediate Point ( Dynamic )Domain: "00:11:22:33:44:55.6666", MD Level: 7 
          Association: "VSNLMEG1", Destination MAC Type: Multicast, VLAN "v3" with 2 cfm ports 
          Transmit Interval: 1000 ms,  Type : ITU-T Y.1731 Maintenance Entity Group   
          port 1; Up End Point,   mepid: 100, transmit-interval: 1000 ms (from association)
                MEP State: Enabled, CCM Message: Enabled, Send SenderId TLV: Disabled         
                Faulting State               : No         
                Last Faulting State Change   : Wed Jun 19 09:10:10 2013         
                MEP Error Defects            : None         
                Port Status                  : Up   
          port 15; Intermediate Point ( Dynamic ) 
          Association: "short_ma_name", Destination MAC Type: Multicast, VLAN "v4" with 2 cfm ports 
          Transmit Interval: 1000 ms,  Type : IEEE 802.1ag Maintenance Association   
          port 1; Up End Point,   mepid: 100, transmit-interval: 1000 ms (from association)         
          MEP State: Enabled, CCM Message: Enabled, Send SenderId TLV:
          Enabled IPaddress:  
        10.10.10.1         
                Faulting State               : No         
                Last Faulting State Change   : Wed Jun 19 09:15:08 2013         
                MEP Error Defects            : None         
                Port Status                  : Up   
          port 15; Intermediate Point ( Dynamic )
Total Number of Domain             : 4
Total Number of Association        : 8
Total Number of Up MEP             : 4
Total Number of Down MEP           : 4
Total Number of MIP                : 4
Total Number of CFM port           : 12
Total Number of SW MEP             : 4
Total Number of HW MEP              : 4
Total Number of VPLS MIP(Static/Up): 0 / 0

================================================================================
MEP Error Defect Types:  
          Remote : Not receiving CCMs from Remote MEP  
          Error  : Erroneous CCM received  
          XCON   : Cross-connect CCM received 
          RDI    : Remote Defect Indication sent by some MEP

History

This command was first available in ExtremeXOS 11.4.

Transmit Interval and MEP State were added in ExtremeXOS 12.3.

Platform Availability

This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X690, and X695 series switches.