Displays detailed system-related information.
mgmt | Specifies the management port. |
port_list | Specifies one or more ports of slots and ports. |
tag | Specifies an 802.1Q or 802.1ad tag value. |
detail | Specifies detailed port information. |
N/A.
This command displays information, including the following:
If you do not specify a port number, range of ports, or tag value, detailed system-related information is displayed for all ports. The data is displayed in a table format.
The tag value may be associated with either a VMAN or a VLAN.
This status information may be useful for your technical support representative if you have a network problem.
The detail parameter is used to provided more specific port information. The data is called out with written explanations versus displayed in a table format.
Note
The detail parameter displays slightly different information depending on the platform and configuration you are working with.The link filter counter displayed with the detail parameter is calculated at the middle layer on receiving an event. The link filter up indicates the number of link transitions from down to up at the middle layer filter.
The following command displays port system-related information on a switch:
# show ports 25 information ELSM/ Port Flags Link OAM/ Link Num Num Num Jumbo QOS Load State MACsec UPS STP VLAN Proto Size profile Master ======================================================================================== 25 Em---------fMB-S-x- active - / -/up 3 0 1 1 9216 none ======================================================================================== > indicates Port Display Name truncated past 8 characters Flags : a - Load Sharing Algorithm address-based, b - Rx and Tx Flow Control Enabled, B - Broadcast Flooding Enabled, D - Port Disabled, e - Extreme Discovery Protocol Enabled, E - Port Enabled, f - Unicast Flooding Enabled, F - Priority Flow Control Enabled, G - MLAG Enabled, i - Isolation, j - Jumbo Frame Enabled, l - Load Sharing Enabled, L - Extreme Link Status Monitoring Enabled, m - MACLearning Enabled, M - Multicast Flooding Enabled, n - Ingress TOS Enabled, o - Dot1p Replacement Enabled, O - Ethernet OAM Enabled, p - Load Sharing Algorithm port-based, P - Software redundant port(Primary), R - Software redundant port(Redundant), s - diffserv Replacement Enabled, S - MACsec Enabled, v - Vman Enabled, w - MACLearning Disabled with Forwarding, x - Rx Flow Control Enabled
# show ports 25 information detail Port: 25 Virtual-router: VR-Default Type: UTP Random Early drop: Unsupported Admin state: Enabled with auto-speed sensing auto-duplex MACsec Link State: Up Link State: Active, 1Gbps, full-duplex Link Ups: 3 Last: Fri Dec 08 16:26:55 2017 Link Downs: 1 Last: Fri Dec 08 16:18:12 2017 VLAN cfg: Name: MACsec_1000, Internal Tag = 1000, MAC-limit = No-limit, Virtual router: VR-Default STP cfg: Protocol: Name: MACsec_1000 Protocol: ANY Match all protocols. Trunking: Load sharing is not enabled. EDP: Disabled EEE: Disabled ELSM: Disabled Ethernet OAM: Disabled MACsec: Enabled
The following example displays the current status of non-Extreme optical devices:
# show ports 3 information detail Port: 3 Virtual-router: VR-Default Type: Q+SR4 (Licensed) or (Unlicensed) or (Restricted) Random Early drop: Unsupported Admin state: Enabled Link State: Ready Link Ups: 0 Last: -- Link Downs: 0 Last: -- VLAN cfg: Name: Default, Internal Tag = 1, MAC-limit = No-limit, Virtual router: VR-Default STP cfg: s0(disable), Tag=(none), Mode=802.1D, State=FORWARDING Protocol: Name: Default Protocol: ANY Match all protocols. Trunking: Load sharing is not enabled. EDP: Enabled ELSM: Disabled Ethernet OAM: Disabled Learning: Enabled Unicast Flooding: Enabled Multicast Flooding: Enabled Broadcast Flooding: Enabled Jumbo: Disabled Flow Control: Rx-Pause: Enabled Tx-Pause: Disabled Priority Flow Control: Disabled Reflective Relay: Disabled Link up/down SNMP trap filter setting: Enabled Egress Port Rate: No-limit (Restricted, 10 Gbps maximum) Broadcast Rate: No-limit Multicast Rate: No-limit Unknown Dest Mac Rate: No-limit QoS Profile: None configured Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled
The following output displays show port info detail that has port-specific tag.
Port: 3 Virtual-router: None Type: BASET Random Early drop: Unsupported Admin state: Enabled with 10G full-duplex Link State: Active, 1Gbps, full-duplex Link Ups: 0 Last: Wed Jun 05 00:29:24 2013 Link Downs: 0 Last: -- VLAN cfg: Name: test, 802.1Q Tag = 200, MAC-limit = No-limit, Virtual router: VR-Test Port-specific VLAN ID: 10, 11, 200 Name: test2, 802.1Q Tag = 300, MAC-limit = No-limit, Virtual router: VR-Default STP cfg: Protocol: Trunking: Load sharing is not enabled. EDP: Disabled ELSM: Disabled Ethernet OAM: Disabled Learning: Enabled Unicast Flooding: Enabled Multicast Flooding: Enabled Broadcast Flooding: Enabled Jumbo: Enabled, MTU= 9216 Flow Control: Rx-Pause: Enabled Tx-Pause: Disabled Priority Flow Control: Disabled Reflective Relay: Disabled Link up/down SNMP trap filter setting: Enabled Egress Port Rate: No-limit Broadcast Rate: No-limit Multicast Rate: No-limit Unknown Dest Mac Rate: No-limit QoS Profile: None configured Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled Ingress 802.1p Examination: Enabled Ingress 802.1p Inner Exam: Disabled Egress IPTOS Replacement: Disabled Egress 802.1p Replacement: Disabled NetLogin: Disabled NetLogin port mode: Port based VLANs Smart redundancy: Enabled Software redundant port: Disabled IPFIX: Disabled Metering: Ingress, All Packets, All Traffic IPv4 Flow Key Mask: SIP: 255.255.255.255 DIP: 255.255.255.255 IPv6 Flow Key Mask: SIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff DIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff Far-End-Fault-Indication: Disabled Shared packet buffer: default VMAN CEP egress filtering: Disabled Isolation: Off PTP Configured: Disabled Time-Stamping Mode: None Configured Port Partition: 4x10G Current Port Partition: 4x10G Available Port Partitions: 1x40G, 4x10G, 1x100G, 2x50G, 4x25G Synchronous Ethernet: Unsupported Dynamic VLAN Uplink: Disabled VM Tracking Dynamic VLANs: Disabled Forward-Error-Correction: Disabled
The following example shows LRM/MACsec Adapter port state information (in bold):
# show ports 3 information detail Port: 3 Virtual-router: VR-Default Type: SF+_CX1m (Unsupported) (LRM/MACsec Adapter) LRM/MACsec Adapter port state: Operational Random Early drop: Unsupported Admin state: Enabled with 10G full-duplex Link State: Active, 10Gbps, full-duplex Link Ups: 1 Last: Fri Aug 16 12:07:01 2019 Link Downs: 0 Last: -- VLAN cfg: Name: Default, Internal Tag = 1, MAC-limit = No-limit, Virtual router: VR-Default STP cfg: s0(enable), Tag=(none), Mode=802.1D, State=FORWARDING Protocol: Name: Default Protocol: ANY Match all protocols. Trunking: Load sharing is not enabled. EDP: Enabled ELSM: Disabled Ethernet OAM: Disabled MACsec: Disabled Learning: Enabled Link-Flap Detection: Disabled Unicast Flooding: Enabled Multicast Flooding: Enabled Broadcast Flooding: Enabled Jumbo: Disabled Flow Control: Rx-Pause: Enabled Tx-Pause: Disabled Priority Flow Control: Disabled Reflective Relay: Disabled Link up/down SNMP trap filter setting: Enabled Egress Port Rate: No-limit Broadcast Rate: No-limit Multicast Rate: No-limit Unknown Dest Mac Rate: No-limit QoS Profile: None configured Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled Ingress 802.1p Examination: Enabled Ingress 802.1p Inner Exam: Disabled Ingress 802.1p Priority: 0 Egress IPTOS Replacement: Disabled Egress 802.1p Replacement: Disabled NetLogin: Disabled NetLogin port mode: Port based VLANs Smart redundancy: Enabled Software redundant port: Disabled IPFIX: Disabled Metering: Ingress, All Packets, All Traffic IPv4 Flow Key Mask: SIP: 255.255.255.255 DIP: 255.255.255.255 IPv6 Flow Key Mask: SIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff DIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff Far-End-Fault-Indication: Disabled Shared packet buffer: default VMAN CEP egress filtering: Disabled Isolation: Off PTP Configured: Disabled Time-Stamping Mode: None Dynamic VLAN Uplink: Disabled VM Tracking Dynamic VLANs: Disabled
The following command displays the indication that a 25G lane-based optic has been inserted into a port partitioned for 10G lanes (lines 4-5):
switch-model-EXOS.6 # show port 25 information detail Port: 25 Virtual-router: VR-Default Type: Q28+SWDM4 (Mismatches Partition) Random Early drop: Unsupported Admin state: Enabled with 40G full-duplex Link State: Ready Link Ups: 0 Last: -- Link Downs: 0 Last: -- VLAN cfg: Name: Default, Internal Tag = 1, MAC-limit = No-limit, Virtual router: VR-Default STP cfg: s0(enable), Tag=(none), Mode=802.1D, State=DISABLED Protocol: Name: Default Protocol: ANY Match all protocols. Trunking: Load sharing is not enabled. EDP: Enabled ELSM: Disabled Ethernet OAM: Disabled MACsec: Disabled Learning: Enabled Link-Flap Detection: Disabled Unicast Flooding: Enabled Multicast Flooding: Enabled Broadcast Flooding: Enabled Jumbo: Disabled Flow Control: Rx-Pause: Enabled Tx-Pause: Disabled Priority Flow Control: Disabled Reflective Relay: Disabled Link up/down SNMP trap filter setting: Enabled Egress Port Rate: No-limit Broadcast Rate: No-limit Multicast Rate: No-limit Unknown Dest Mac Rate: No-limit QoS Profile: None configured Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled Ingress 802.1p Examination: Enabled Ingress 802.1p Inner Exam: Disabled Ingress 802.1p Priority: 0 Egress IPTOS Replacement: Disabled Egress 802.1p Replacement: Disabled QOS Profile Settings: QP1 MinBw = 0% MaxBw = 100% MaxBuf = 100% Weight = 1 QP8 MinBw = 0% MaxBw = 100% MaxBuf = 100% Weight = 1 NetLogin: Disabled NetLogin port mode: Port based VLANs Smart redundancy: Enabled Software redundant port: Disabled IPFIX: Disabled Metering: Ingress, All Packets, All Traffic IPv4 Flow Key Mask: SIP: 255.255.255.255 DIP: 255.255.255.255 IPv6 Flow Key Mask: SIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff DIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff Far-End-Fault-Indication: Disabled Shared packet buffer: default VMAN CEP egress filtering: Disabled Isolation: Off PTP Configured: Disabled Time-Stamping Mode: None Port Partition: 1x40G Available Port Partitions: 1x40G, 4x10G, 2x50G, 4x25G Dynamic VLAN Uplink: Disabled VM Tracking Dynamic VLANs: Disabled Forward-Error-Correction: Disabled
The following command displays the indication that a 100G optic has been inserted into an unlicensed port (lines 4-5):
switch-model-EXOS.6 # show port 1 info detail Port: 1 Virtual-router: VR-Default Type: Q28+SWDM4 (Mismatches Partition) (Unlicensed) Random Early drop: Unsupported Admin state: Enabled with 10G full-duplex Link State: Ready Link Ups: 0 Last: -- Link Downs: 0 Last: -- VLAN cfg: STP cfg: Protocol: Trunking: Load sharing is not enabled. EDP: Enabled ELSM: Disabled Ethernet OAM: Disabled MACsec: Disabled Learning: Enabled Link-Flap Detection: Disabled Unicast Flooding: Enabled Multicast Flooding: Enabled Broadcast Flooding: Enabled
The following command displays port information with ingress filtering for MAC-based VLANs enabled:
switch-model-EXOS.6 # show ports 1:2 information detail Port: 1:2 Virtual-router: VR-Default Type: UTP Random Early drop: Unsupported Admin state: Enabled with auto-speed sensing auto-duplex Link State: Ready Link Ups: 0 Last: -- Link Downs: 0 Last: -- VLAN cfg: Name: SYS_VLAN_0300, Internal Tag = 300(MAC-Based with ingress filtering on), MAC-limit = No-limit, Virtual router: VR-Default Name: SYS_VLAN_0301, Internal Tag = 301(MAC-Based with ingress filtering on), MAC-limit = No-limit, Virtual router: VR-Default Name: SYS_VLAN_0500, 802.1Q Tag = 500, MAC-limit = No-limit, Virtual router: VR-Default Port-specific VLAN ID: 500 Name: SYS_VLAN_0501, 802.1Q Tag = 501, MAC-limit = No-limit, Virtual router: VR-Default Port-specific VLAN ID: 501 STP cfg: Protocol: Name: SYS_VLAN_0301 Protocol: ANY Match all protocols. Name: SYS_VLAN_0300 Protocol: ANY Match all protocols. Trunking: Load sharing is not enabled. EDP: Enabled EEE: Disabled ELSM: Disabled Ethernet OAM: Disabled MACsec: Disabled Learning: Enabled Link-Flap Detection: Disabled Unicast Flooding: Enabled Multicast Flooding: Enabled Broadcast Flooding: Enabled Jumbo: Disabled Flow Control: Rx-Pause: Enabled Tx-Pause: Disabled Priority Flow Control: Disabled Reflective Relay: Disabled Link up/down SNMP trap filter setting: Enabled Egress Port Rate: No-limit Broadcast Rate: No-limit Multicast Rate: No-limit Unknown Dest Mac Rate: No-limit QoS Profile: None configured Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled Ingress 802.1p Examination: Enabled Ingress 802.1p Inner Exam: Disabled Ingress 802.1p Priority: 0 Egress IPTOS Replacement: Disabled Egress 802.1p Replacement: Disabled QOS Profile Settings: QP1 MinBw = 0% MaxBw = 100% MaxBuf = 100% Weight = 1 QP8 MinBw = 0% MaxBw = 100% MaxBuf = 100% Weight = 1 NetLogin: Disabled NetLogin port mode: MAC based VLANs with ingress filtering on Smart redundancy: Enabled Software redundant port: Disabled IPFIX: Disabled Metering: Ingress, All Packets, All Traffic IPv4 Flow Key Mask: SIP: 255.255.255.255 DIP: 255.255.255.255 IPv6 Flow Key Mask: SIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff DIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff auto-polarity: Enabled Shared packet buffer: default VMAN CEP egress filtering: Disabled Isolation: Off PTP Configured: Disabled Time-Stamping Mode: None Dynamic VLAN Uplink: Disabled VM Tracking Dynamic VLANs: Disabled
The following command displays port information for ports 23 and 24 with MDI and MDIX mode configured and auto-polarity disabled:
# show port 23 information detail | in polarity auto-polarity: Disabled (MDI)
# show port 24 information detail | in polarity auto-polarity: Disabled (MDIX)
This command was first available in ExtremeXOS 10.1.
Information on ingress rate shaping was added in ExtremeXOS 11.0.
Network Login, Smart Redundancy, and rate limiting were added in ExtremeXOS 11.1.
Information on unicast, multicast, and broadcast flooding; the Port not present parameter; and autopolarity status were added in ExtremeXOS 11.2.
The netlogin parameters were added in ExtremeXOS 11.3.
The output command was modified in ExtremeXOS 12.1 so that when learning is disabled with the disabled learning port command, a new w flag appears in the output.
Link Ups and Link Downs information was added to the output and the tag value was added to the command syntax in ExtremeXOS 12.4.4.
Industrial Temperature detail added to Type field in ExtremeXOS 15.1.2.
Note
The Industrial Temperature detail is only displayed only when detail is used. Without it, the output is compressed and the optic type is not displayed.The show output was enhanced to display the SNMP ifMib ifAlias accessible string size information.
The show output was updated to include the current status of non-Extreme optical devices in ExtremeXOS 15.4.
Link-flap detection information was added in ExtremeXOS 22_1.
Available Port Partitions was added to show port speed licensing information for ExtremeSwitching X870-96x-8c switches in ExtremeXOS 22.2.
IEEE Forward Error Correction (FEC) Clause 74 or 91 modes status was added in ExtremeXOS 22.3.
MACsec flag (S) and LRM/MACsec adapter in the detail Type field was added in ExtremeXOS 30.1.
LRM/MACsec Adapter port state information was added in ExtremeXOS 30.4.
Mismatched port compatility indication was added in ExtremeXOS 31.3.
Ingress filtering for MAC-based VLANs was added in ExtremeXOS 31.5.
mdi-mode information was added in version 32.6.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X690, and X695 series switches.