Allows you to choose the destination MAC type for sending CFM PDUs for an MA.
domain_name |
Enter the domain associated with the MA you are configuring. |
association_name |
IEEE 802.1ag or ITU-T Y.1731 association name. |
unicast |
CFM PDUs are sent to the unicast MAC address configured in static remote MEP creation. |
multicast |
CFM PDUs are sent to the standard multicast destination address. |
Multicast.
Use this command to change the MAC type on a previously configured MA. If multicast is selected, CFM PDUs are sent to the standard multicast destination. If unicast is selected, CFM PDUs are sent to the unicast MAC address configured in static remote MEP creation.
Use the show cfm command to verify your configuration.This command was first available in ExtremeXOS 12.1.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X690, and X695 series switches.