Displays the current switch information.
On a SummitStack, this command displays the Master and Backup node information if executed on the Master, and displays the current node and the Master node information if executed on any other node.
This command has no arguments or variables.
N/A.
This information may be useful for your technical support representative if you have a problem.
On a SummitStack, the System UpTime may be useful when manually resolving the dual master situation. For more information, see Eliminating a Dual Master Situation Manually section in the ExtremeXOS 32.6.1 User Guide .
Depending on the software version running on your switch, additional or different switch information may be displayed.
Output from this command on the standalone ExtremeSwitching series switch looks similar to the following:
SysName: SummitX SysLocation: SysContact: support@extremenetworks.com, +1 888 257 3000 System MAC: 00:04:96:26:6B:EC System Type: SummitX SysHealth check: Enabled (Normal) Recovery Mode: All System Watchdog: Enabled Trusted Delivery: UBOOT Image Verified Current Time: Wed Apr 25 21:17:18 2012 Timezone: [Auto DST Disabled] GMT Offset: 0 minutes, name is UTC. Boot Time: Wed Apr 25 21:13:54 2012 Boot Count: 951 Next Reboot: None scheduled System UpTime: 3 minutes 24 seconds Current State: OPERATIONAL Image Selected: secondary Image Booted: secondary Primary ver: 12.0.0.4 Secondary ver: 12.0.0.4Config Selected: primary.cfg Config Booted: primary.cfg Config Automatic: primary.cfg primary.cfg Created by ExtremeXOS version 22.2.0.16 344404 bytes saved on Tue Jan 17 11:17:56 2017 Auto-saved every 2 minutes. Next periodic save on Tue Jan 17 14:45:33 2017 LAA MAC: Locally Administered MAC Address Enabled Port Name Pattern: eths\sp\p (After Reboot: slot\sport\p) show version Slot-1 : 800908-00-01 1847F-10076 Rev 01 IMG: 30.3.0.453 VIM5-4XE-1 : 800910-00-01 1845F-10106 Rev 01 XN-SSD-001-120-1: 800954-00-02 1917F-10030 Rev 02 Image : ExtremeXOS version 30.3.0.453 by release-manager on Thu Jul 11 11:52:10 EDT 2019 Diagnostics : Certified Version : EXOS Linux 4.14.123, FIPS fips-ecp-2.0.16 Build Tools Version : exos-x32-sdk-2.5.3.1.0
The show switch detail command displays the same information shown above. Output from this command on a stack looks similar to the following:
SysName: Stack SysLocation: SysContact: support@extremenetworks.com, +1 888 257 3000 System MAC: 02:04:96:27:B7:41 System Type: X (Stack) SysHealth check: Enabled (Normal) Recovery Mode: All System Watchdog: Enabled Current Time: Tue Jan 30 14:22:41 2007 Timezone: [Auto DST Disabled] GMT Offset: 0 minutes, name is UTC. Boot Time: Mon Jan 29 21:51:38 2007 Boot Count: 317 Next Reboot: None scheduled System UpTime: 16 hours 31 minutes 3 seconds Slot: Slot-4 * Slot-5 ------------------------ ------------------------ Current State: MASTER BACKUP (In Sync) Image Selected: secondary secondary Image Booted: secondary secondary Primary ver: 12.0.0.10 12.0.0.10 Secondary ver: 12.0.0.13 12.0.0.13 Config Selected: primary.cfg Config Booted: primary.cfg primary.cfg Created by ExtremeXOS version 12.0.0.10 139108 bytes saved on Fri Jan 26 22:56:40 2007 LAA MAC: Locally Administered MAC Address Disabled Port Name Pattern: eths\sp\p (After Reboot: eths\sp\p)
Slot-1 VPEX Stack.12 # sh switch SysName: Stack SysLocation: SysContact: https://www.extremenetworks.com/support/ System MAC: 02:04:96:9B:B7:87 System Type: VPEX X670G2-48x-4q (Stack) SysHealth check: Enabled (Normal) Recovery Mode: All System Watchdog: Enabled Current Time: Wed May 6 23:54:50 2020 Timezone: [Auto DST Disabled] GMT Offset: 0 minutes, name is UTC. Boot Time: Wed May 6 23:15:57 2020 Boot Count: 2405 Next Reboot: None scheduled System UpTime: 38 minutes 53 seconds Slot: Slot-1 * Slot-2 ------------------------ ------------------------ Current State: MASTER BACKUP (vpex Not Synced) Image Selected: secondary secondary Image Booted: secondary secondary Primary ver: 30.7.0.102 30.7.0.102 Secondary ver: 31.1.0.108 31.1.0.108 Config Selected: primary.cfg Config Booted: primary.cfg Config Automatic: NONE (Disabled) primary.cfg Created by ExtremeXOS version 31.1.0.74 951802 bytes saved on Mon Apr 20 19:34:02 2020
This command was first available in ExtremeXOS 10.1.
This command was updated to support stacking in ExtremeXOS 12.0 and the System Type was added to the output from this version.
Automatic configuration save information was added in ExtremeXOS 22.2.
Locally administered per-port MAC address information was added in ExtremeXOS 22.3.
System port name pattern information added in ExtremeXOS 30.1.
Solid State Storage Device SSD-120 information was added in ExtremeXOS 30.3.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X690, and X695 series switches.