ExtremeXOS Feature Compatibility with V400 Virtual Port Extenders shows which ExtremeXOS features are supported, or are not supported, or that have limitations when used with V400 Virtual Port Extenders.
ExtremeXOS Feature | Status |
---|---|
ACLs |
Ingress (first and second stage) and egress ACLs are supported with the following
limitations:
Note: When installing ACL rules bound to a set
of ports, rules are replicated for each port if there are ACL counters and counter
compression is not enabled or if the ports are extended ports.
Note: You can consume an excessive
number of ACLs if you bind them to each individual (extended) port in cases where you have
many extended ports. To avoid this, consider policy (role-based assignments per user) for
access-control (see Policy Roles), ACLs bound to
VLANs, wildcarded applications (see Configuring the ACL Rule on the Interface
), or two-stage ACLs (see Two-Stage ACL).
|
AVB | Not supported. |
BFD | Supported, except on extended ports. |
CFM | Supported, except on extended ports. |
Diffserv examination | Supported. |
Disable slot | Not supported. Note: You can take a BPE
slot offline by disabling the corresponding cascade port(s).
|
Dot1p examination | Disabled by default on extended ports; enabled by default on controlling bridge cascade ports. Use cascade port Dot1p examination for extended port traffic to conserve ACL hardware resources. |
EAPS | Supported, except that EAPS ring ports cannot be extended ports. |
EDP/LLDP/CDP | Supported. Note: BPEs will not appear as EDP neighbors.
|
EEE | Supported. |
ELSM | Not supported. |
ERPS | Supported, except that ERPS ring ports cannot be extended ports. |
ESRP | Not supported. |
Fabric Attach |
ExtremeXOS Fabric
Attach (FA) supports FA servers and FA Proxies to be Extended Edge
Switching controlling bridge (CB) nodes connected
with bridge port extenders (BPEs) in two different topologies:
|
FDB | |
FDB: Limit learning | Supported. |
FDB: MAC lockdown | Supported. |
FDB: Static and blackhole entries | Supported, except that multi-port unicast FDBs entries are not supported. |
Flood rate-limit | Not supported on extended ports. |
HcLAG | Not supported. |
Identity Management | Identity Management should not be enabled on cascade ports. |
L2 PBR | Not supported. |
FDB: multi-port unicast entries | Not supported. |
L3 | |
L3: PBR | Supported. |
L3: Gateway routers | Gateway router connected to extended port LAGs is not supported. |
L3: IP unicast forwarding | Maximum gateways (using configure iproute sharing max-gateways max_gateways ) must be greater than or equal to the number of active extended LAG members. |
L3: Routing protocols |
Supported on CB; not supported on extended ports. |
L3 Tunnels |
Supported on CB ports. Not supported on extended ports. |
LAG: LACP |
Supported. The default and only supported algorithm on extended port LAGs is "custom." |
V400 Virtual Port Extender LEDs | Supported. For information about the location of BPE LEDs, see the V400 Virtual Port Extender Quick Reference Guide. |
Mirroring |
Mirroring extended ports is supported. Mirroring to extended ports is supported on all Universal platforms. Ingress mirroring of an extended port will include an 802.1BR
E-tag.
Note: Workaround: You can avoid this 802.1BR E-tag by doing the following:
Mirroring to BPE cascade ports is not supported. Limitations: Only known traffic to extended ports can be egress mirrored. |
MLAG | Supported on cascade ports; not supported on extended ports. Not supported on cascade ports when in stacking mode. |
MPLS/VPLS | Not supported. |
Multicast | |
Multicast: IGMP | Supported. |
Multicast: MVR | Supported. |
Multicast: PIM | Supported. |
Multicast: PIM Snooping | Supported. |
MVRP | Supported. |
Netlogin | Dot1X and MAC Auth supported, and supported with MLAG. Not
supported:
WebAuth is not supported with MLAG.
|
Node Alias | Supported. |
OnePolicy |
Basic policy supported:
|
PoE | Supported on select BPE models. See Supported Bridge Port Extender Models. Operator limit configuration is not supported on cascade ports. |
Ports | |
Ports: Flooding | Disabling flooding is supported. |
Ports: Jumbo frame |
Enabling/disabling jumbo support on extended ports is supported; cascade-ports default to jumbo enabled. The max-frame-size on V400 is enforced only on ingress, and not on egress. |
Ports: Learning | Disabling/enabling learning supported. |
PVLAN | Not supported. |
QoS |
Supported:
Not supported:
Note: Dot1p examination is enabled by
default on cascade ports, but disabled by default on extended ports.
Note: When using
hyrbid QoS scheduling, strict-priority queues must be the highest number queues.
|
Restart port | Not supported on extended ports. Use disable/enable port commands. |
sFlow | Supported: sFlow hardware sampling on Extended Edge Switching extended ports is provided by the underlying Extended Edge Switching cascade port hardware. As such, the configured sample rate is programmed on the cascade port and is provided in aggregate to all subtended sFlow-enabled Extended Edge Switching extended ports. |
Software-redundant ports | Supported. |
STP | Supported, primarily for edge loop detection (edge guard); supported with MLAG redundancy for RSTP and MSTP protocol modes. |
VLAN | |
VLAN:Membership |
Supported; users specify VLAN membership using <slot>:<port> notation; protocol VLANs not supported. |
VLAN: statistics | Supported on extended ports. Note: VLAN
flood traffic is not counted in the transmit counters; displayed counts include an
additional 8 bytes for the Ethertype + E-tag encapsulation.
|
VMAN/CEP | Not supported. |
VMT/XNV | Not supported. |
VRRP | Supported. |
VXLAN |
Supported for tagged and untagged tenant VLANs on extended ports, except for ExtremeSwitching 5420 and 5520 series switches. Extended port LAG in VXLAN is not supported. Extended ports cannot be in VXLAN network VLANs. Extended ports cannot participate in RIOT configurations. Ring is not supported for VXLAN extended ports. Optimized IP Multicast Replication is not supported for VXLAN extended ports. |