Configuring VLAN multicast stream limitation members
Configure multicast stream limitation members on ports of a specific VLAN to limit the number of multicast groups that can join a VLAN.
Procedure
Example
Enable multicast stream limitation on ports 2/3 to 2/8 and configure the maximum allowed number of streams to 6 for this interface.
Switch:1(config-if)# ip igmp stream-limit-group 2/3-2/8 max-streams 6
Variable definitions
Use the data in the following table to use the ip igmp stream-limit-group command.
Variable |
Value |
---|---|
<0–65535> |
Configures the maximum number of allowed streams for the specified ports on this VLAN. The range is from 0–65535 and the default is 4. |
{slot/port[/sub-port] [-slot/port[/sub-port]] [,...]} |
Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port. |