Note
This procedure only applies to 5320 Series and 5420 Series.
Perform this procedure to increase the number of SPB nodes per area that the switch supports. For more information about maximum scaling numbers, see Fabric Engine Release Notes.
If you enable this boot config flag, it decreases the scaling limits for the following features:
Switched UNI (S-UNI) endpoints
Layer 2 and Layer 3 I-SIDs
IP Multicast over Fabric Connect local streams
Private VLANs
The scaling numbers for the following items are limited by the use of a shared hardware resource, and thus they affect one another:
the number of SPB nodes per area
the number of SPB nodes that send IP Multicast streams that the local BEB receives
local SPB services:
Layer 2 I-SIDs
Layer 3 I-SIDs
IP Multicast over Fabric Connect remote IP Multicast stream data I-SIDs
I-SID mirroring instances
If you enable this boot config flag:
The switch supports up to 500 nodes per area.
The switch supports up to 200 nodes per area, when all of them are concurrently sending IP Multicast over Fabric Connect streams while local BEB receives.
The switch supports a maximum of 500 Switched UNI (S-UNI) endpoints.
If you disable this boot config flag (default configuration):
The switch supports up to 350 nodes per area.
The switch supports up to 150 nodes per area, when all of them are concurrently sending IP Multicast over Fabric Connect streams while local BEB receives.
The switch supports a maximum of 1,000 Switched UNI (S-UNI) endpoints.
enable
configure terminal
boot config flags spbm-node-scaling
show boot config flags
save config
reset
Enable the boot config flag to increase the number of SPB nodes per area that switch supports.
Switch:1>en Switch:1#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch:1(config)#boot config flags spbm-node-scaling Switch:1(config)#save config Switch:1(config)#reset Warning: Please save the configuration and reboot the switch for this configuration to take effect.
Note
Flag support can vary across hardware models.
Switch:1#show boot config flags flags advanced-feature-bandwidth-reservation low flags block-snmp false flags debug-config false flags debugmode false flags dvr-leaf-mode false flags enhancedsecure-mode false flags factorydefaults false flags flow-control-mode true flags ftpd true flags hsecure false flags ipv6-egress-filter true flags ipv6-mode false flags logging true flags macsec false flags nni-mstp false flags reboot true flags spanning-tree-mode mstp flags spbm-config-mode true flags spbm-node-scaling true flags sshd true flags syslog-rfc5424-format true flags telnetd true flags tftpd true flags trace-logging false flags urpf-mode true flags verify-config true flags vrf-scaling true