Configuring the Counter Sampling Interval
Configure the counter sampling interval values at port level to determine how often the sFlow agent polls and exports counters for a configured interface.
Before you begin
You must globally enable sFlow.
Procedure
Example
Verify all slots use the default polling-interval configuration.
Switch:1(config-if)#sflow counter-interval 525 Switch:1(config-if)#show sflow interface 1/1-1/10 =============================================================================== sFlow Port Configuration Info =============================================================================== Port Packet-Sample-Rate Max-Header-Size Counter-interval Collector-list (in secs) -------------------------------------------------------------------------------- 1/1 0 128 525 1,2 1/2 0 128 525 1,2 1/3 0 128 525 1,2 1/4 0 128 525 1,2 1/5 0 128 525 1,2 1/6 0 128 525 1,2 1/7 0 128 525 1,2 1/8 0 128 525 1,2 1/9 0 128 525 1,2 1/10 0 128 525 1,2 -------------------------------------------------------------------------------- All 10 out of 10 Total Num of sflow port entries displayed
Variable Definitions
Use the data in the following table to use the sflow counter-interval and show sflow interface commands.
Variable |
Value |
---|---|
<1–3600> |
Specifies the polling interval for a slot. Default value is 0 (disabled). |
{slot/port[/sub-port] [-slot/port[/sub-port]] [,...]} |
Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port. |