Viewing information about Ethernet errors

View information about Ethernet errors to display information about the types of Ethernet errors sent and received by a specific MLT or all MLTs.

About this task

Important

Important

The IMAC columns refer to internal MAC address errors.

Procedure

  1. Enter Privileged EXEC mode:

    enable

  2. View information about Ethernet errors:

    show mlt error main [<1-512>]

Example

Switch:1#show mlt error main 40

================================================================================
                               Mlt Ethernet Error
================================================================================
MLT  ALIGN   FCS     IMAC    IMAC    CARRIER FRAMES  SQETEST DEFER
ID   ERROR   ERROR   TRNSMIT RECEIVE SENSE   TOOLONG ERROR   TRNSMSS
--------------------------------------------------------------------------------
40    0       0       0       0       0       0       0       0

Variable definitions

Use the data in the following table to use the show mlt error main command.

Variable

Value

<1-512>

Specifies the MLT ID. The value ranges from 1–512.