ipv6 bfd (for a VLAN)
Enable and configure Bidirectional Forwarding
Detection (BFD) on a VLAN.
Note
BFD for IPv6 interfaces is a
demonstration feature on some products. For more information about feature
support, see VOSS Feature Support Matrix.
Command Parameters
- enable
- Enable BFD on a VLAN.
- interval
- Specifies the transmit
interval in milliseconds. The default is 200 ms.
- The minimum value for the transmit interval is 100 ms. You can configure a
maximum of 4 BFD sessions with the minimum value for the transmit interval. You can
configure the remaining BFD sessions with a transmit interval that is greater than or equal to the
200 ms default value.
- min-rx
- Specifies the receive interval in milliseconds. The default is 200 ms.
- The minimum value for the receive interval is 100 ms. You can configure a
maximum of 4 BFD sessions with the
minimum value for the receive interval. You can configure the remaining BFD sessions with a receive
interval that is greater than or equal to the 200 ms default value.
- multiplier
- Specifies the multiplier used
to calculate the amount of time BFD waits before it
declares a receive timeout. The default is 3.
- If you configure the transmit interval or the receive interval as 100 ms,
you must configure a value of 4 or greater for the multiplier.
- vlan <1-4094>
-
Specifies the VLAN ID in the range of 1-4094.
Default
The default is disabled.
Command Mode
VLAN Interface Configuration