Alarm

This page provides an overview of RMON Alarm entries. Each page shows up to 99 entries from the Alarm table, default being 20, selected through the entries per page input field. When first visited, the web page will show the first 20 entries from the beginning of the Alarm table. The first displayed will be the one with the lowest ID found in the Alarm table.

Click to expand in new window
Object Description
ID Indicates the index of Alarm control entry.
Interval Indicates the interval in seconds for sampling and comparing the rising and falling threshold.
Variable Indicates the particular variable to be sampled.
Sample Type The method of sampling the selected variable and calculating the value to be compared against the thresholds.
Value The value of the statistic during the last sampling period.
Startup Alarm The alarm that may be sent when this entry is first set to valid.
Rising Threshold Rising threshold value.
Rising Index Rising event index.
Falling Threshold Falling threshold value.
Falling Index Falling event index.
Buttons
Refresh the page automatically every three seconds.
Refresh the page immediately. Any non-committed changes will be lost.
Update the table starting from the first entry in the table.
Update the table starting with the entry after the last entry currently displayed.