Delete |
Check to delete the entry. It will be deleted during the next save. |
ID |
Indicates the index of the entry. The range is from 1 to 65 |
Interval |
Indicates the interval in seconds for sampling and comparing the rising and falling threshold. The range is 1 – 2^31-1. |
Variable |
Indicates the particular variable to be sampled. Possible variables are:
- InOctets: The total number of octets received on the interface, including framing characters.
- InUcastPkts: The number of unicast packets delivered to a higher-layer protocol.
- InNUcastPkts: The number of broad-cast and multi-cast packets delivered to a higher-layer protocol.
- InDiscards: The number of inbound packets that are discarded even the packets are normal.
- InErrors: The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.
- InUnknownProtos: the number of the inbound packets that were discarded because of the unknown or un-support protocol.
- OutOctets: The number of octets transmitted out of the interface, including framing characters.
- OutUcastPkts: The number of uni-cast packets that request to transmit.
- OutNUcastPkts: The number of broad-cast and multi-cast packets that request to transmit.
- OutDiscards: The number of outbound packets that are discarded event the packets is normal.
- OutErrors: The The number of outbound packets that could not be transmitted because of errors.
- OutQLen: The length of the output packet queue (in packets).
|
Sample Type |
The method of sampling the selected variable and calculating the value to be compared against the thresholds. Possible sample types are:
- Absolute: Get the sample directly.
- Delta: Calculate the difference between samples (default).
|
Value |
The value of the statistic during the last sampling period. |
Startup Alarm |
The method of sampling the selected variable and calculating the value to be compared against the thresholds. Possible sample types are:
- Rising: Trigger alarm when the first value is larger than the rising threshold.
- Falling: Trigger alarm when the first value is less than the falling threshold.
- RisingOrFalling: Trigger alarm when the first value is larger than the rising threshold or less than the falling threshold (default).
|
Rising Threshold |
Rising threshold value (-2147483648 – 2147483647). |
Rising Index |
Rising event index (1 – 65535). |
Falling Threshold |
Falling threshold value (-2147483648 – 2147483647) |
Falling Index |
Falling event index (1 – 65535). |