MLAG

The MLAG feature allows you to combine ports on two switches to form a single logical connection to another network device. The other network device can be either a server or a switch that is separately configured with a regular LAG (or appropriate server port teaming) to form the port aggregation.
Note

Note

If there is already an MLAG configuration on the switch before connecting to ExtremeCloud, the MLAG becomes a configuration of the ExtremeCloud. Thereafter, any changes to the MLAG configuration must be applied only from the ExtremeCloud - you cannot do MLAG configuration changes directly on the switch.

The following diagram displays the elements in a basic MLAG configuration:

Click to expand in new window
MLAG Elements
GUID-92622472-C822-48E2-886B-966818B91143-low.png
  1. MLAG port that is a load-shared link. This port is the peer MLAG port for <Switch2:Port P2>.
  2. MLAG peer switch for Switch 2.
  3. Inter-switch connection (ISC or ISC VLAN) has only the ISC port as a member port on both MLAG peers.
  4. ISC link that connects MLAG peers.
  5. MLAG peer switch for Switch 1.
  6. ISC ports.
  7. MLAG port that is a non-load-shared link. This port is the peer MLAG port for <Switch1:Port P1>.
  8. MLAG group (MLAG-ID 1) that has two member ports (one load-shared and one non-load-shared member).
  9. MLAG remote node sees the MLAG ports as regular load-shared link.
  10. MLAG remote node - can be a server or a switch.

The operation of this feature requires two ExtremeXOS switches interconnected by an Inter-Switch connection (ISC). The ISC is a normal, directly connected, Ethernet connection and it is recommended that you engineer reliability, redundancy where applicable, and higher bandwidth for the ISC connection. Logically aggregate ports on each of the two switches by assigning MLAG identifiers (MLAG-ID). Ports with the same MLAG-ID are combined to form a single logical network connection. Each MLAG can be comprised of a single link or a LAG on each switch. When an MLAG port is a LAG, the MLAG port state remains up until all ports in the LAG go down.

As long as at least one port in the LAG remains active, the MLAG port state remains active. When an MLAG port (a single port or all ports in a LAG) fails, any associated MAC entries are moved to the ISC, forcing traffic destined to the MLAG to be handled by the MLAG peer switch. Additionally, the MLAG peer switch is notified of the failure and changes its ISC blocking filter to allow transmission to the MLAG peer port. In order to reduce failure convergence time, you can configure MLAG to use ACLs for redirecting traffic via the "fast" convergence-control option.

Each of the two switches maintains the MLAG state for each of the MLAG ports and communicates with each other to learn the MLAG states, MAC FDB entries, and IP multicast entries of the peer MLAG switch.