Configures the Fabric Attach Zero Touch Client.
zero-touch-client | Specifies Zero Touch Client. |
client | Specifies the type of Fabric Attach client. |
vlan | Specifies the VLAN on which to configure Zero Touch Clients. |
vlan_name | Specifies the VLAN name. The VLAN must be a tagged VLAN. |
vlan_id | Specifies the VLAN ID tag (1 and 4,094). |
nsi | Network Service Identifier. |
nsi | Specifies the Network Service Identifier. Range is 1-16777215. |
insi | Individual Network Service Identifier |
insi | Specifies the Individual Network Service Identifier. Range is 1-16777215. |
priority | Specifies the Zero Touch port priority for untagged packets. |
priority | Specifies the priority number to be used for untagged packets. Range is 0-7. |
dot1p | Specifies the use of dot1p port priority for untagged packets (default). |
none | Specifies no Zero Touch Client VLAN in use. |
enable | Specifies enabling Zero Touch Clients. |
disable | Specifies disabling Zero Touch Clients (default). |
Unless configured, all clients are configured to disabled state without a mapping.
This command is only used when operating as a Fabric Attach server. It has no effect when operating as a client or proxy.
The specified VLAN configuration on the Fabric Attach server is restricted to only tagged VLANs.
The following example configures the Fabric Attach Zero Touch Client "switch" with a VLAN named "V2000" and Individual Service Identifier of 2000 with a priority of 1 for untagged packets:
# configure fabric attach zero-touch-client switch vlan v2000 nsi 2000 priority 1
This command was first available in ExtremeXOS 31.3.
This command is available on ExtremeSwitching 5320, 5420, 5520, and 5720 series switches.