This command clears both frame-delay and frame-loss information for segment with given segment name.
segment_name |
An alpha numeric string identifying the segment name. |
N/A.
Use this command to clear both frame-delay and frame-loss information for segment with given segment name.
# clear co cfm seg cs2 # # sho cfm seg cs2 CFM Segment Name : cs2 Domain Name : dom1 Association : a2 MD Level : 1 Destination MAC : 00:04:96:52:a7:38 Frame Delay: DMM Transmission : In Progress Transmission Mode : On Demand Total Frames to be sent : 45 Frames Transmitted : 0 Pending Frames : 40 Frames Received : 0 DMM Tx Interval : 10 secs DMR Rx Timeout : 50 msec Alarm Threshold : 10 % Clear Threshold : 95 % Measurement Window Size : 60 Class of Service : 6 Tx Start Time : None Min Delay : None Max Delay : None Last Alarm Time : None Alarm State : None Lost Frames : 0 Frame Loss: LMM Tx Interval : 10 secs SES Threshold : 1.000000e-02 Consecutive Available Count : 4 Measurement Window Size : 1200 Class of Service : 6 Total Configured MEPs : 1 Total Active MEPs : 1 MEP ID : 2 LMM Transmission : In Progress Transmission Mode : On Demand Total Frames to be sent : 45 Frames Transmitted : 0 Pending Frames : 40 Frames Received : 0 Availability Status : Idle Unavailability Start Time : None Unavailability End Time : None Press <SPACE> to continue or <Q> to quit: Tx Start Time : None ----------------------------------------------------------- Total Configured Segments : 11 Total Active Segments : 11 # # # # # # # #
This command was first available in ExtremeXOS 15.1.
This command is available on ExtremeSwitching 5320, 5420, 5520, and 5720 series switches.