configure cfm segment window

configure cfm segment segment_name window size

Description

Configures the measurement window size.

Syntax Description

segment_name

An alpha numeric string identifying the segment name.

size

Specifies the number of frames to be used for delay measurement. The range is 1 to 1800.

Default

60 frames.

Usage Guidelines

Use this command to configure the window size to be used for calculating the threshold values. This window size denotes the total number of recent frames for which the threshold values are to be measured.

This is an optional command and if not configured, the lower of either the default value or the total number of frames sent is used.

Note

Note

MEPs with intervals 3 and 10 cannot be created in this domain as the domain name format is of dns type.

Example

The following command configures the measurement window size for the CFM segment segment-first at 55:

configure cfm segment segment-first window 55

History

This command was first available in ExtremeXOS 12.3.

Platform Availability

This command is available on ExtremeSwitching 5320, 5420, 5520, and 5720 series switches.