configure inline-power label ports
configure inline-power label string ports port_list
Description
Lets you create your own label for a specified PoE port or group of PoE ports.
Syntax Description
string
|
Specifies a name up to 15
characters in length to identify the specified power
port(s). |
port_list
|
Specifies one or more ports or
slots and ports. |
Usage Guidelines
Use the show inline-power
configuration ports command, as shown in the following
example, to display inline power configuration information, including the label (if
any) for each port:
show inline-power configuration port 3:1-10
Following is sample output from this command on a SummitStack:
Port Config Operator Limit Priority Label
3:1 Enabled 16000 mW Low finance
3:2 Enabled 15000 mW Low finance
3:3 Enabled 15000 mW Low
3:4 Enabled 15000 mW Low
3:5 Enabled 15000 mW Low
3:6 Enabled 15000 mW Low marketing
3:7 Enabled 15000 mW Low marketing
3:8 Enabled 15000 mW Low marketing
3:9 Enabled 15000 mW Low
3:10 Enabled 15000 mW Low
Example
The following command
assigns the name “alpha-test_1” to port 1 on slot 4:
config inline-power label alpha-test_1 ports 4:1
History
This command was
first available in ExtremeXOS 11.1.
Platform Availability
This command is available on:
- ExtremeSwitching
5420F-8W-16P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-24P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-16MW-32P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-16W-32P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-48P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-48P-4XL—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420M-16MW-32P-4YE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5320-48P-8XE—ExtremeXOS 31.6 and
later.
- ExtremeSwitching
5320-24P-8XE—ExtremeXOS 31.6 and
later.
- ExtremeSwitching
5320-16P-4XE—ExtremeXOS 31.7 and
later.
- ExtremeSwitching
5320-16P-4XE-DC—ExtremeXOS 31.7 and
later.
- ExtremeSwitching 5520-24W—ExtremeXOS 31.1 and later.
- ExtremeSwitching 5520-48W—ExtremeXOS 31.1 and later.
- ExtremeSwitching 5520-12MW-36W—ExtremeXOS 31.1 and later.
- ExtremeSwitching 5420F-8W-16P-4XE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420F-16MW-32P-4XE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420F-16W-32P-4XE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420M-24W-4YE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420M-16MW-32P-4YE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420M-48W-4YE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5720-24MW—Switch Engine 32.1 and later.
- ExtremeSwitching 5720-24MXW—Switch Engine 32.1 and later.
- ExtremeSwitching 5720-48MW—Switch Engine 32.1 and later.
- ExtremeSwitching 5720-48MXW—Switch Engine 32.1 and later.