configure cfm segment transmit-interval

configure cfm segment segment_name {frame-delay | frame loss}transmit-interval interval

Description

Configures the transmission interval of DMM frames.

Syntax Description

segment_name An alpha numeric string identifying the segment name.
frame-delay Y.1731 Ethernet Frame Delay Measurement.
frame loss Y.1731 Ethernet Frame Loss Measurement.
interval Specifies the transmit interval in seconds. The range is 1 to 90.

Default

10 seconds.

Usage Guidelines

Use this command to configure the delay between two consecutive DMM frames. The configured delay is for both continuous and on-demand transmission. This command is optional, and if not configured the default interval is used.

Example

The following example configures a transmission interval of 5 seconds for segment s2.

configure cfm segment s2 transmit-interval 5

History

This command was first available in ExtremeXOS 12.3.

Platform Availability

This command is available on ExtremeSwitching 5320, 5420, 5520, and 5720 series switches.