If the user specifies the mode as continuous, the LMM transmission will continue till it is stopped by the user.
enable cfm segment frame-loss measurement segment_name mep mep_id [continuous | count frames]This command is used to trigger LMM frames at the configured transmit-interval.
segment_name | An alpha numeric string identifying the segment name. |
continuous | Specifies that frames are to be sent continuously until stopped. |
count | Specifies that a number of frames are to be sent. |
frames | Specifies the number of frames to send. The range is 1 to 4294967295. |
N/A.
This command is used to trigger LMM frames at the configured transmit-interval. If the user specifies the mode as continuous, the LMM transmission will continue till it is stopped by the user.
Note
If the user tries to trigger the LMM frames for a segment which is not completely configured, the frames will not be transmitted for that segment, and an error message will be thrown.enable cfm segment cs2 frame-loss measurement mep 3 count 10 enable cfm segment cs2 frame-loss measurement mep 3 continuous
This command was first available in ExtremeXOS 15.1.
This command is available on ExtremeSwitching 5320, 5420, 5520, and 5720 series switches.