configure stpd loop-protect event-window

configure stpd stpd_name loop-protect event-window interval

Description

Configures the interval for which loop protect events are counted by the loop protect event threshold.

Syntax Description

stpd_name Specifies an STPD name on the switch.
interval The length of the interval, in seconds, over which the loop protect event threshold is defined. The valid range is 0–255 seconds.

Default

By default the interval is set to 180 seconds.

Usage Guidelines

None.

Example

The following example sets the loop protect event window to 120 seconds for STP domain r1.

configure stpd r1 loop-protect event-window 120

History

This command was first available in ExtremeXOS 15.7.1.

Platform Availability

This command is available on ExtremeSwitching 5320, 5420, 5520, and 5720 series switches.