disable inline-power slot
Description
Shuts down PoE power currently provided to the specified slot.
Syntax Description
| slot | Disables inline power to specified slot. |
Default
Enable.
Usage Guidelines
Disabling inline power to a slot immediately removes power to any connected PDs. By default, the capability to provide inline power to a slot is enabled.

Note
You can set the reserved power budget to 0 for a slot if, and only if, you first issue this command.
On a stack if you do not specify a slot number, the command operates on all active nodes. This command operates only on nodes in the active topology.
Example
The following command removes power to all PDs on slot 3:
disable inline-power slot 3
History
This command was first available in ExtremeXOS 11.1.
Platform Availability
This command is available on the PoE devices listed in Extreme Networks PoE Devices.