unconfigure inline-power usage-threshold
Description
Unconfigures the inline power usage alarm threshold and returns threshold to the default value of 70%.
Syntax Description
This command has no arguments or variables.
Default
70.
Usage Guidelines
This command unconfigures the PoE usage threshold setting for initiating SNMP event and EMS messages and returns the switch‘s inline power usage threshold for to 70%. The system initiates an event and message once that percentage of the budgeted power is being used.
On stand-alone switches, this PoE threshold applies to the entire switch.
The system generates an additional SNMP event and EMS message once the power usage falls below the threshold again; once the condition clears.
Example
The following command resets the inline power usage alarm threshold to 70%:
unconfigure inline-power usage-threshold
History
This command was first available in ExtremeXOS 11.1
Platform Availability
This command is available on the PoE devices listed in Extreme Networks PoE Devices.