show network-clock ptp
Description
Show the PTP clock recovery state information. The clock recovery using PTP event messages undergoes the following servo state changes:
-
Warmup - The local reference clock is in warmup state.
-
Fast Loop - The local reference clock is being corrected and the correction is converging.
-
Bridge - The local reference clock correction has been interrupted due to changes in the clocking information in the received PTP event messages or loss of PTP event messages.
-
Holdover - Prolonged loss of PTP event messages puts the local reference clock correction to holdover state.
-
Normal - The local reference clock correction has converged and the corrected clock is synchronous to the master clock information received in the PTP event messages.
Syntax Description
N/A.
Default
N/A.
Usage Guidelines
See Description.
Example
# show network-clock ptp ===================================================================== Servo State Information ===================================================================== Servo State : 3 (Normal Loop) Servo State Duration : 10285 (sec) =====================================================================
History
This command was first available in ExtremeXOS 15.1.
Platform Availability
This command is available on Summit X460-G2, X670-G2, and X770 series switches.

Note
PTP commands can be used only with the Network Timing feature pack.