show bootprelay configuration

show bootprelay configuration {ipv4 | ipv6} {{vlan vlan_name } | {vr vr_name}}

Description

Displays the enabled/disabled configuration of BOOTP relay on one or all VLAN (Virtual LAN)s for the specified VR.

Syntax Description

bootprelay

BOOTP Relay Configuration

ipv4

DHCPv4 BOOTP Relay service.

ipv6

DHCPv6 BOOTP Relay service.

vlan VLAN
vlan_name Specifies a single VLAN for which to display BOOTP relay configuration information.
vr Use a specific virtual router name.
vr_name Specifies a single VR for which to display BOOTP relay configuration information.

Default

IPv4.

Usage Guidelines

If a VR is not specified, this command displays the specified VLANs for the current VR context.
Note

Note

ExtremeXOS DHCPv6 supports three options: OPTION_RELAY_MSG (9), OPTION_INTERFACE_ID (18), and OPTION_REMOTE_ID (37).
Note

Note

It is mandatory to configure BOOTP Relay v6 Agents. The packets are not forwarded if the v6 agents are not configured.

Example

The following example displays the BOOTP relay configuration for all VLANs on the VR-Default virtual router:

Switch.88 # show bootprelay configuration vr "VR-Default"
BOOTP Relay : Enabled on virtual router "VR-Default"
VLAN                                    BOOTP Relay
--------------------------------        -----------
Default                                 Disabled
client1                                 Enabled
serv                                    Enabled

The following example displays the BOOTP relay configuration for all VLANs in the current VR context:

Switch.95 # show bootprelay configuration
BOOTP Relay : Enabled on virtual router "VR-Default"
VLAN                                    BOOTP Relay
--------------------------------        -----------
Default                                 Disabled
client1                                 Disabled
serv                                    Disabled

The following example displays the BOOTP relay configuration for VLAN client1:

Switch.87 # show bootprelay configuration vlan "client1"
BOOTP Relay : Enabled on virtual router "VR-Default"
VLAN                                    BOOTP Relay
--------------------------------        -----------
client1                                 Disabled
The following example displays the BOOTP relay configuration for IPv6:
* Switch # show bootprelay configuration ipv6
DHCPv6 BOOTP Relay : Enabled on virtual router "VR-Default" 
VLAN                                     DHCPv6 BOOTP Relay
--------------------------------          ------------------
Default                                        Enabled
The following example displays the BOOTP relay configuration for IPv6 when vr is disabled:
* Switch  # show bootprelay configuration ipv6
DHCPv6 BOOTP Relay : Disabled on virtual router "VR-Default"
The following example shows DHCP/BOOTP relay configuration that is disabled for the VR, but enabled on some VLANs:
# show bootprelay configuration 
DHCPv4 BOOTP Relay : Disabled on virtual router "VR-Default", but enabled on some VLANs.
    Include Secondary    : Disabled
    BOOTP Relay Servers  : 
    DHCP Relay Agent Information Option: Disabled
    DHCP Relay Agent Information Check : Disabled
    DHCP Relay Agent Information Policy: Replace

History

This command was first available in ExtremeXOS 12.4.2.

Information about DHCP/BOOTP relay being disabled for the VR, but enabled on some VLANs was added in ExtremeXOS 22.5.

Platform Availability