This command configures DHCPv4 server/next hop relay for each VLAN (Virtual LAN) IPv4 interfaces. This command is not applicable to IPv6 interfaces. Configuring bootprelay per VLAN v4 level is supported only on IPv4, and not on IPv6.
bootprelay | BOOTP Relay service. |
add | Adds DHCP (Dynamic Host Configuration Protocol) BOOTP Relay server. |
delete | Deletes DHCP BOOTP Relay server. |
ip_address | IP address of bootp relay server. |
N/A.
Use this command to configure the DHCPv4 server/next hop for each VLAN interface. The configuration applied to the VR level is populated to all VLAN v4 IPv4/v6 interfaces.
The following example displays IPv6 bootprelay information:
# sh bootprelay configuration ipv4 DHCPv4 BOOTP Relay : Enabled on virtual router "VR-Default" Include Secondary : Disabled BOOTP Relay Servers : 10.127.6.243 DHCP Relay Agent Information Option: Disabled DHCP Relay Agent Information Check : Disabled DHCP Relay Agent Information Policy: Replace VLAN DHCPv4 BOOTP Relay ------------------------ ------------------ VLAN "Default": BOOTP Relay : Enabled VLAN "client": BOOTP Relay : Enabled BOOTP Relay Servers : 10.1.1.1 10.127.6.101 10.127.6.243 DHCP Relay Agent Information Option: Disabled DHCP Relay Agent Information Check : Disabled DHCP Relay Agent Information Policy: Replace VLAN "client1": BOOTP Relay : Enabled VLAN "dhcpv4server": BOOTP Relay : Enabled VLAN "server": BOOTP Relay : Enabled
This command was first available in ExtremeXOS 15.5.