configure erps neighbor port

configure erps ring-name neighbor-port port

Description

Add RPL (ring protection link) neighbor configuration for the ERPS (Ethernet Ring Protection Switching) ring.

Syntax Description

ring-name Alphanumeric string that identifies the ERPS ring.
port The slot:port number for RPL neighbor.

Default

N/A.

Usage Guidelines

Use this command to add RPL neighbor configuration for the ERPS ring.

Note

Note

This command implicitly makes the node on which it is configured the RPL neighbor.

Example

The following command adds RPL neighbor on port 5 to an ERPS ring named “ring1”:

configure erps ring1 neighbor-port 5

History

This command was first available in ExtremeXOS 15.1.

Platform Availability

This command is available on all platforms supported in 12.6 and forward that are running ExtremeXOS.