Filter Events

To conduct fault management on an access point:

  1. Select DiagnosticsFault ManagementFilter Events.

    The screen displays by default. Use this screen to configure how events are tracked. By default, all events are enabled, and an administrator has to turn off events that do not require tracking.

    Click to expand in new window
    Fault Management - Filter Events screen
    GUID-FBFAAAB5-13AE-469A-A86D-8C5DA72BFB2C-low.png
  2. Use the Filter Events screen to create filters for managing detected events. Events can be filtered based on severity, module received, source MAC, device MAC and client MAC address.

  3. Define the following Customize Event Filters parameters for the Fault Management configuration:

    Severity

    Set the filtering severity. Select from the following:

    All Severities – All events are displayed, irrespective of their severity

    Critical – Only critical events are displayed

    Error – Only errors and above are displayed

    Warning – Only warnings and above are displayed

    Informational – Only informational and above events are displayed

    Module

    Select the module from which events are tracked. When a module is selected, events from other modules are not tracked. Remember this when interested in events generated by a particular module. Individual modules can be selected (such as TEST, LOG, FSM etc.) or all modules can be tracked by selecting All Modules.

    Source

    Set the MAC address of the source device to be tracked. Setting a MAC address of 00:00:00:00:00:00 allows all devices to be tracked.

    Message Substring

    Optionally append a text message (substring) to the event filter to assist the administrator in distinguishing this filter from others with similar attributes.

    Note

    Note

    Leave the fields to a default value of 00:00:00:00:00:00 to track all MAC addresses.
  4. Select the Add to Active Filters button to create a new filter and add it to the Active Event Filters table. When added, the filter uses the current configuration defined in the Customize Event Filters field.

  5. Refer to the Active Event Filters table table to set the following parameters:

    1. To activate all the events in the Active Events Filters table, select the Enable All Events button. To stop event generation, select Disable All Events.
    2. To enable an event in the Active Event Filters table, select the event, then select the Activate Defined Filter(s) button.
Note

Note

Filters cannot be persisted across sessions. They must be created every time a new session is established.