To add/edit an Imagotag policy:
Enable | Select to enable the policy. |
Channel | Use this drop-down menu to configure the channel assigned
for the ESL communicator to tag communication in the 2.4 GHz
band. The option are:
|
Window Size | Use the spinner control to set the
transmission window size for messages exchanged between ESL
communicator and tags.
Note: SES-Imagotags recommends
NOT to change the default setting.
|
Payload Size | Use the spinner control to set the
maximum size of the payload in packets exchanged between ESL
communicator and tags.
Note: SES-Imagotags recommends
NOT to change the default setting.
|
Output Power | Use the spinner control to
configure the maximum output power for the ESL communicator.
The options are:
Note: SES-Imagotags recommends
NOT to change the default setting, which is in
conformance to various country/region specific RF
regulations.
|
SSL | Select to enable secure, encrypted communication over the SSL (Secure Socket Layer) between the AP and SES-imagotag server. This option is disabled by default. |
FCC-Mode | Select to enable the FCC (Federal Communications Commission) compatibility mode on the ESL communicator. This option is disabled by default. |
Server ID |
Use this field to specify the Imagotag
server's IP address or hostname. As per the current implementation, at the ESL server end, the WiNG AP‘s IP address was configured to enable the server contact the AP and establish connection with the ESL communicator (USB Dongle). Starting with WiNG 5.9.3, it is the AP that initiates communication with the ESL Imagotag server. The AP sends a connection request to the ESL server specified here. |
Port |
Use the spinner control to set the port on which the Imagotag server is reachable. The default value is 7353. |