password access-level

Enable CLI access levels to control the configuration actions of various users

Syntax

Command Parameters

access level WORD<2-8>
Allows or blocks this access level.
aging-time day <1-365>
Configures the expiration period for passwords in days, from 1-365.
default-lockout-time <60-65000>
Changes the default lockout time after three invalid attempts. Configures the lockout time, in seconds, and is in the 60-65000 range.
min-passwd-len <10-20>
Configures the minimum length for passwords in high-secure mode.
password-history <3-32>
Specifies the number of previous passwords the switch stores. You cannot reuse a password that is stored in the password history.
WORD<2-8>
Permits or blocks this access level. The available access levels are:
  • l1

  • l2

  • l3

  • ro

  • rw

  • rwa

Default

By default, all access levels are permitted.

Command Mode

Global Configuration