show sys power

View power information for the chassis.

Syntax

Default

None

Command Mode

User EXEC

Command Output

The show sys power command displays the following information:

Output field

Description

Chassis Power Status

Displays if the chassis contains redundant power.

Chassis Type

Displays the type of chassis.

Total Chassis Power

Displays the power currently used by the complete chassis.

Required Redundant Power

Displays the redundant power for the chassis.

Max Allocated Power

Displays the maximum power.

Available Power

Displays the available, unused, power.

Reserved Power

Displays the reserved power.

Required Power

Displays the required power.

Example

The following example displays summary power information.

Switch:1#show sys power

==========================================================================================
                           Chassis Power Information
==========================================================================================
Chassis Power Status: non-redundant

                             Total     Required  Max
Chassis                      Chassis   Redundant Allocated Available Reserved Required
Type                         Power     Power     Power     Power     Power    Power
------------------------------------------------------------------------------------------
5320-48T-8XE-FabricEngine    90        0         75        15        75       75
------------------------------------------------------------------------------------------