show ipv6 bfd interfaces

Display Bidirectional Forwarding Detection (BFD) configuration for a port or VLAN on an IPv6 interface.

Syntax

Command Parameters

{slot/port[/sub-port] [-slot/port[/sub-port]] [,...]}

Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port.

vlan <1-4059>

Specifies the VLAN ID in the range of 1 to 4059. By default, VLAN IDs 1 to 4059 are configurable and the system reserves VLAN IDs 4060 to 4094 for internal use. On switches that support the vrf-scaling and spbm-config-mode boot configuration flags, if you enable these flags, the system also reserves VLAN IDs 3500 to 3998. VLAN ID 1 is the default VLAN and you cannot create or delete VLAN ID 1.

Command Mode

User EXEC

Usage Guidelines

BFD for IPv6 interfaces is a demonstration feature on some products. For more information about feature support, see Fabric Engine and VOSS Feature Support Matrix.

Command Output

The show ipv6 bfd interfaces command displays the following information:

Output field

Description

VLAN

Specifies the VLAN ID. The system displays this field only in output for VLAN interfaces.

PORT

Specifies the port number. The system displays this field only in output for GigabitEthernet interfaces.

STATUS

Specifies whether BFD is enabled on the interface.

MIN_RX

Specifies the receive interval in milliseconds.

INTERVAL

Specifies the transmit interval in milliseconds.

MULTIPLIER

Specifies the multiplier used to calculate the amount of time BFD waits before declaring a receive timeout.

Example

The following example displays port configuration information for BFD.

Switch:1>show ipv6 bfd interfaces gigabitethernet 1/3

==========================================================================================
                                    Port Bfd
==========================================================================================
PORT       STATUS     MIN_RX     INTERVAL   MULTIPLIER      VRF-ID
------------------------------------------------------------------------------------------
1/3        enable     200        200            3           0