Create and configure a connectivity-association (CA).
Note
Configure a CA name in multiples of 4 characters (4 bytes). If the total number of characters in a CA name is not a multiple of 4, it can create interoperability issues with EXOS or Switch Engine products.
macsec connectivity-association WORD<5-32> connectivity-association-key WORD<10-64> [key-parity {even | odd}]
no macsec connectivity-association WORD<5-32> connectivity-association-key WORD<10-32>
even — generates even-numbered keys
odd — generates odd-numbered keys
Note
This parameter only applies to static MACsec configurations.
None
Global Configuration