ipv6 bfd (for a VLAN)

Enable and configure Bidirectional Forwarding Detection (BFD) on a VLAN.

Syntax

Command Parameters

enable
Enable BFD on a VLAN.
interval
Specifies the transmit interval in milliseconds. The default is 200 ms.
The minimum value for the transmit interval is 100 ms. You can configure a maximum of 4 BFD sessions with the minimum value for the transmit interval. You can configure the remaining BFD sessions with a transmit interval that is greater than or equal to the 200 ms default value.
min-rx
Specifies the receive interval in milliseconds. The default is 200 ms.
The minimum value for the receive interval is 100 ms. You can configure a maximum of 4 BFD sessions with the minimum value for the receive interval. You can configure the remaining BFD sessions with a receive interval that is greater than or equal to the 200 ms default value.
multiplier
Specifies the multiplier used to calculate the amount of time BFD waits before it declares a receive timeout. The default is 3.
If you configure the transmit interval or the receive interval as 100 ms, you must configure a value of 4 or greater for the multiplier.
vlan <1-4094>

Specifies the VLAN ID in the range of 1-4094.

Default

The default is disabled.

Command Mode

VLAN Interface Configuration

Usage Guidelines

BFD for IPv6 interfaces is a demonstration feature on some products. For more information about feature support, see Fabric Engine Feature Support Matrix.