Use the Time Range Entry Configuration page to configure periodic and absolute time range entries and add them to named time ranges.
Note
The time range entries use the system time for the time periods in which they take effect. Make sure you configure the SNTP (Simple Network Time Protocol) server settings so that the SNTP client on the switch can obtain the correct date and time from the server.To access this page, click
in the navigation menu.To configure the time range entries for a time range configuration, select the time range configuration from the Time Range Name menu and use the buttons to perform the following tasks:
Field | Description |
---|---|
Time Range Name | Select the name of the time range to which you want to add a time range entry. |
Time Range Entry | Select Create New Time Range Entry to add a new entry to a time range. To view or delete an existing time range entry, select its ID from the menu. |
Time Range Entry ID | When creating a new time range entry, assign a unique ID number from 1–10. This field does not appear if the entry has already been configured. |
Time Range Entry Type. | Specifies whether the entry is periodic or absolute. A periodic entry occurs at the same time every day or on one or more days of the week. An absolute entry does not repeat. |
Periodic Time Range Entry | |
Applicable Days | Specify the day(s) when the time entry occurs:
|
Start Day | (Periodic Days of Week only) Select the day the time range entry starts. To select multiple days, hold the [Ctrl] key and click the days. |
Start Time | Specify the time when the entry begins. The time is based on a 24-hour clock. For example, 6:00 PM is 18:00. |
End Day | (Periodic Days of Week only) Select the day the time range entry ends. |
End Time | Specify the time when the entry ends. The time is based on a 24-hour clock. For example, 6:00 PM is 18:00. |
Absolute Time Range Entry | |
Absolute Start Date and Time | Select the checkbox to configure the date and time when the time range entry begins. |
Start Month | Select the month when the time entry begins. |
Start Date | Select the day of the month when the time entry begins. |
Start Year | Select the year when the time entry begins. |
Start Time | Specify the time when the entry begins. The time is based on a 24-hour clock. For example, 6:00 PM is 18:00. |
Absolute End Date and Time | Select the checkbox to configure the date and time when the time range entry ends. |
End Month | Select the month when the time entry ends. |
End Date | Select the day of the month when the time entry ends. |
End Year | Select the year when the time entry ends. |
End Time | Specify the time when the entry ends. The time is based on a 24-hour clock. For example, 6:00 PM is 18:00. |
If you change any of the parameters, click Submit to apply the changes to the system. If you want the switch to retain the new values across a power cycle, you must save the configuration.
Configuration changes take effect immediately.