The following V300 Virtual Port Extender models are available:
V300-8P-2X V300-8T-2X V300HT-8P-2X V300HT-8T-2X |
Height:1.73 in (4.4 cm) Width: 7.76 in (19.71 cm) Length: 212 in (538.48 cm) |
V300-8P-2T-W | Height: 1.73 in (4.4 cm) Width: 8.26 in (21 cm) Length: 7.48 in (19 cm) |
V300-8P-2X V300-8T-2X V300HT-8P-2X V300HT-8T-2X |
3.31 lb (1.5 kg) |
V300-8P-2T-W | 3.22 lb (1.46 kg) |
V300-8P-2X | Height: 3.07 in (7.79 cm) Width: 11.52 in (29.26 cm) Length: 19.98 in (50.74 cm) |
V300-8T-2X | Height: 3.07 in (7.79 cm) Width: 10.15 in (25.78 cm) Length: 17.61 in (44.72 cm) |
V300-8P-2T-W | Height: 3.08 in (7.82 cm) Width: 10.85 in (27.56 cm) Length: 11.52 in (29.26 cm) |
V300HT-8P-2X V300HT-8T-2X |
Height: 3.07 in (7.79 cm) Width: 10.15 in (25.78 cm) Length: 14.46 in (36.72 cm) |
V300-8P-2X with 280W PSU |
7.94 (3.6 kg) |
V300-8T-2X with 40W PSU |
5.73 lb (2.6 kg) |
V300-8P-2T-W | 4.1 lb (1.86 kg) |
V300HT-8P-2X V300HT-8T-2X |
3.97 (1.8kg) |
Note
When you use a redundant power supply (RPS), only redundant power – not additive power – is supported. Thus, the PoE ports load does not increase when an RPS is added.V300-8P-2X | DC Input: 54VDC, 4.5A max |
V300-8T-2X | DC Input: 12VDC, 1.5A max |
V300-8P-2T-W | The PoE PSE Budget is dynamically determined by the
802.3bt Type 4 PD input power applied to its uplinks as follows:
|
V300HT-8P-2X | DC Input: 54VDC, 4.5A max |
V300HT-8T-2X | DC Input: 12VDC, 1.5A max |
Minimum Heat Dissipation (BTU/hr) | Minimum Power Consumption (Watts) | Maximum Heat Dissipation (BTU/hr) | Maximum Power Consumption (Watts) | |
---|---|---|---|---|
V300-8P-2X | 25.9 | 7.6W | 118.2 | 214.6W |
V300-8T-2X | 11.6 | 3.3W | 23.8 | 7.0W |
V300-8P-2T-W | 24.57 | 7.2W | 82.1 | 129.1W |
V300HT-8P-2X | 25.8 | 7.6W | 113.7 | 213.3W |
V300HT-8T-2X | 16.6 | 4.9W | 7.4 | 25.2W |
Minimum is defined as idle, with no ports linked. Maximum is defined as fans high, all ports 100% traffic.
North American Safety of ITE |
UL 60950-1 2nd Ed., A2:2014, Listed Device (US) CSA 22.2 #60950-1-07 2nd Ed., 2014-10 Canada) Complies with FCC 21CFR 1040.10 (US Laser Safety) CDRH Letter of Approval (US FDA Approval) |
European Safety of ITE |
EN 60950-1:2006 +A11+A1+A12+A2 EN 60825-1:2007 (Lasers Safety) IEC 60950-1:2005 2nd+A1:2009+A2:2013 2014/35/EU Low Voltage Directive |
International Safety of ITE |
CB Report & Certificate per IEC 60950-1:2005 2nd Ed. + National Differences AS/NZX 60950-1 (Australia /New Zealand) |
Operating conditions |
Temperature: 0°C to 60°C (32°F to 140°F) for V300 8P-2T-W and V300-8P/8T-2X models Temperature: -40°C to 70°C (-40°F to 158°F) for V300HT-8P/8T-2X models Storage and transportation temperature: -40°C to 70°C (-40°F to 158°F) Humidity: 5% to 95% relative humidity, non-condensing Altitude: 0 to 3,000 meters (9,850 feet) |