Half-Duplex to Full-Duplex Converter Technical Specifications

The Half-Duplex to Full-Duplex Converter can be attached to switch ports to enable communication over half-duplex connections with older Ethernet devices.

Order the converter using one of the following part numbers:
  • 10958: HDX to FDX Converter, Rest of World
  • 10959: HDX to FDX Converter: North America
Other specifications:
  • 8.8 Gbps switching capacity
  • 4 priority queues
  • 192Kb packet buffer
Table 1. Half-Duplex to Full-Duplex Converter Packaged Dimensions
Height 2.69 cm (1.06 in)
Width 12.9 cm (5.08 in)
Depth 6.91 cm (2.72 in)
Weight 200 g (0.44 lb)

Half-Duplex to Full-Duplex Converter Power Specifications

Table 2. Rest of the World External Power Pack (10958-CEE 7/1)
Voltage input range 200-240 VAC
Line frequency range 50 to 60 Hz
Operating temperature 0°C to 40°C (32°F to 104°F) normal operation
Table 3. North American External Power Pack (10959-NEMA 1-15P)
Voltage input range 100-120 VAC
Line frequency range 50 to 60 Hz
Operating temperature 0°C to 40°C (32°F to 104°F) normal operation

Half-Duplex to Full-Duplex Converter Environmental Data and Standards

Table 4. Environmental Data
Environmental conditions Operating temperature: 0°C to 40°C (32°F to 104°F)

Storage temperature: -40°C to 70°C (-40°F to 158°F)

Humidity: 10% to 95% relative humidity, non-condensing

Altitude: 0 to 2,000 meters (6,562 feet)

Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks

Packaged vibration: 5 to 62 Hz at velocity 5 mm/s, 62 to 500 Hz at 0.2 G

Packaged random vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct. from 20 to 200 Hz

Packaged drop height: 14 drops minimum on sides and corners at 42 inches (<15 kg box)

Table 5. Safety Standards

North American ITE

UL 60950-1 2nd Ed., Listed Device (U.S.)

CSA 22.2 #60950-1-03 2nd Ed. (Canada)

Complies with FCC 21CFR 1040.10 (U.S. Laser Safety)

European/International ITE

EN 60950-1:2007 2nd Ed.

CB Report & Certificate per IEC 60950-1 2nd Ed. + National Differences

AS/NZS 60950-1 (Australia /New Zealand)

EMI/EMC Standards

FCC CFR 47 part 15 Class A (USA)

ICES-003 Class A (Canada)

EN 55022: Class A

EN 55024:A2 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11

EN 61000-3-2,8 (Harmonics)

EN 61000-3-3 (Flicker)

2014/30/EU EMC Directive

International EMC Certifications

CISPR 22: Ed 5.2, Class A (International Emissions)

CISPR 24:A2: Class A (International Immunity)

IEC 61000-4-2: EN 61000-4-2:2009 Electrostatic Discharge, 8kV Contact, 15 kV Air, Criteria A

IEC 61000-4-3: EN 61000-4-3:2006+A1:2008 Radiated Immunity 10V/m, Criteria A

IEC 61000-4-4: am1 ed.2./EN 61000-4-4:2004/A1:2010 Transient Burst, 1 kV, Criteria A

IEC 61000-4-5: EN 61000-4-5:2006 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A

IEC 61000-4-6: EN 61000-4-6:2009 Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A

IEC/EN 61000-4-11: Power Dips & Interruptions, >30%, 25 periods, Criteria C

IEEE 802.3 Media Access Standards

IEEE 802.3ab 1000BASE-T

IEEE 802.3az EEE

Environmental specifications

EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage

EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation

EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational

ASTM D3580 Random Vibration Unpackaged 1.5 G