This MIB defines the following Extreme-specific SNMPv1 traps generated by Extreme Networks devices.
Trap | Comments |
---|---|
extremeOverheat |
The on-board temperature sensor has reported an overheat condition. The system shuts down until the unit has sufficiently cooled such that operation can begin again. A cold start trap is issued when the unit has come back on line. |
extremeFanfailed |
One or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation. |
extremeFanOK |
A fan has transitioned out of a failure state and is now operating correctly. |
extremeInvalidLoginAttempt |
A user attempted to log into the console or by telnet but was refused access due to an incorrect username or password. |
extremePowerSupplyGood |
One or more previously bad sources of power to this agent has come back to life without causing an agent restart. |
extremePowerSupplyFail |
One or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over. |
extremeEdpNeighborAdded |
This node discovers a new neighbor through EDP (Extreme Discovery Protocol). |
extremeEdpNeighborRemoved |
No EDP updates are received from this neighbor within the configured timeout period and this neighbor entry is aged out by the device. |
extremeModuleStateChanged |
Signifies that the value of the extremeSlotModuleState for the specified extremeSlotNumber has changed. Traps are reported only for significant states. |